Built for circuit protection against overloads and short circuits, the Siemens 3VA5220-7ED61-0AA0 is a 2-pole molded case circuit breaker. It is rated 200A, 600VAC and 500VDC and belongs to the 3VA5 series. Its thermal magnetic trip has fixed thermal and fixed magnetic settings. The LI trip function provides long-time and instantaneous protection. The terminal connection has no lugs.
Alarm Switch, Auxiliary Switch, Motor Operator, Shunt Trip, Undervoltage Release
Standards
IEC 60947-2, UL 489
Approval
CE, CSA, UL, VDE
Temp Rating
-25C to 70C
Construction Features
HACR Rated
Product FAQs
8 answers
How should I select the Siemens 3VA5220-7ED61-0AA0 for load current?
Use its 200A rated current when coordinating the circuit load, conductor sizing and overcurrent protection. Select it where that current rating meets the circuit's protection requirements.
Can this breaker be used on AC or DC circuits?
It is rated 600VAC and 500VDC. Compare the appropriate AC or DC rating with the circuit voltage when selecting the breaker.
How do I evaluate its interrupting rating for a 480V installation?
Its interrupting rating is 100kAIC at 480V. For a 480V installation, verify that the available fault current at the installation point does not exceed that rating.
How does its trip protection work, and can I adjust it?
The thermal-magnetic trip provides thermal overload protection and magnetic short-circuit protection. Its LI function combines long-time and instantaneous protection. Both thermal and magnetic settings are fixed, so select it for an application that does not require field-adjustable trip settings.
What does the no-lugs terminal connection mean for installation?
The breaker has no lugs, so plan the conductor termination method and required termination hardware before installation. Do not plan on landing conductors in integral lugs.
How much space should I account for in the installation layout?
Use its 7.3 in height, 4.1 in width and 4.2 in depth when laying out the installation. Also account for conductor routing and termination access.
What does fixed mounting mean for the installation?
Fixed mounting means the breaker is secured in a stationary installed position. Choose this mounting style when planning a fixed installation.
What does the 2-pole construction mean for conductor protection?
The 2-pole construction provides two protected current paths. Use the pole count when planning which circuit conductors require overcurrent protection.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 4.8 out of 5 based on 9 reviews.