Siemens CPD63B120 3 Pole Circuit Breaker

Siemens CPD63B120 - 1200A 3 Pole Molded Case Circuit Breaker

New

$5,918.90 Check Stock

Quantity

Description

Built to handle massive electrical loads, this 1200A molded case circuit breaker delivers dependable long-time and instantaneous fault protection. It fastens securely into Siemens Type S5 and SPP panelboards, along with Sentron switchboards and motor control centers. Equipped with an interchangeable thermal-magnetic trip unit, this PD-frame component achieves a 100kAIC rating at 480V, offering exceptional current-limiting performance for commercial facilities.

Specifications

Key specifications
Brand Siemens
Part Number CPD63B120
Series CPD
Amperage 1200A
Poles 3
Mounting Style Unit Mount
Voltage 240VAC, 480VAC, 600VAC, 250VDC, 500VDC
Phase 3
AIC Rating 200kA @ 240VAC, 100kA @ 480VAC, 65kA @ 600VAC, 30kA @ 250VDC, 50kA @ 500VDC
Fit and installation
Terminal Type Lugs
For Use With Siemens Type S5 Panelboards, Type SPP Panelboards, Sentron Switchboards, Motor Control Centers
Wire Gauge 3-4 x 300-600 kcmil (Al/Cu)
Max Wire 600 kcmil
Min Wire 300 kcmil
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Adjustable Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch
Accessories Line & Load Lugs
Standards CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489
Approval CE, CSA, HACR, UL
Temp Rating 40C
Construction Features Current Limiting, HACR Rated, Interchangeable Trip Unit

Product FAQs

6 answers
Which Siemens panelboards and switchboards are compatible with the CPD63B120 breaker?

This unit mount PD frame breaker is designed for installation in Siemens Type S5 and Type SPP panelboards, as well as Sentron switchboards and motor control centers.

What are the standard lug wire size requirements for this 1200A breaker?

The factory lugs accept 3 to 4 conductors per phase, accommodating 300 to 600 kcmil aluminum or copper wire. Ensure proper torque specifications are followed during installation to prevent thermal issues.

Does the CPD63B120 feature adjustable trip settings?

Yes, it utilizes a thermal magnetic trip unit with fixed thermal (Long-Time) protection and an adjustable magnetic (Instantaneous) trip function. This allows panel builders to tune the short-circuit response based on the specific load requirements.

Is this breaker rated for direct current (DC) applications?

Yes, in addition to its AC ratings, this breaker is rated for DC systems. It provides a 30kA interrupting capacity at 250VDC and 50kA at 500VDC, making it versatile for specialized industrial power systems.

What frame size does the CPD63B120 belong to?

This breaker is part of the Siemens Sentron series PD frame group. When sourcing internal accessories like shunt trips, undervoltage releases, or auxiliary switches, ensure they are specifically listed for Sentron PD frames.

What is the maximum fault current this breaker can safely interrupt at 480V?

It features a high interrupting rating of 100kA at 480VAC. This robust rating ensures safe clearing of severe faults, making it suitable for heavy industrial facilities with high available fault currents.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.