Maximizing panel capacity, the MP230240CT2 delivers two separate 240V circuits within a compact two-space footprint. It features a 40A inner and 30A outer common trip configuration. Designed for plug-on installation, this quadplex unit mounts into legacy Murray and current Siemens load centers. It serves as an exact match for older systems and is officially replaced by the Q23040CT2. With a 10kAIC rating and HACR certification, it safely handles heavy-duty HVAC equipment.
Can I use the MP230240CT2 to replace an older Murray quad breaker?
Yes, this breaker is designed for use in Murray load centers. Siemens acquired Murray, and this MP-T series breaker is the direct replacement for legacy Murray MH-T quadplex breakers with the same amp ratings.
What is the Siemens equivalent to the MP230240CT2?
The direct Siemens equivalent is catalog number Q23040CT2. Both are manufactured by Siemens and share identical internal components, but the Q23040CT2 is UL listed specifically for Siemens panels under the QT frame type.
How much panel space does this quadplex breaker require?
It requires two standard 1-inch spaces. The quadplex design allows you to fit two independent 2-pole circuits into the physical space normally occupied by a single 2-pole breaker, maximizing panel density.
What does the CT2 suffix mean on this breaker?
The CT2 suffix indicates that both the inner and outer circuits feature an internal common trip. If a fault occurs on one leg of either the 30A or 40A circuit, both legs of that specific circuit will trip simultaneously to prevent a partial power condition on 240V loads.
Does this breaker have a rejection clip?
Yes, this is a Class CTL (Circuit Total Limiting) breaker and features a rejection clip. It can only be installed in load center slots specifically notched to accept tandem or quadplex breakers.
Can I install this Murray MP-T breaker in a Siemens load center?
While Siemens manufactures both brands, you must check your specific Siemens load center wiring diagram. Many Siemens panels list Murray MP-T breakers as acceptable, but if your panel only lists Siemens Type QT, you should use the Q23040CT2 instead to maintain UL compliance.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 4 reviews.
Thank you so much for sending me a 100 amp breaker that was in the condition that you said it would be in.With out your breaker I would still be in the dark Thank you David