Skip to main content
Expedited shipping available at checkout

Square D BGA260504 Molded Case Circuit Breaker

  • 50A
  • 2 Pole
  • I-Line
Square D BGA260504
Molded Case Circuit Breaker
Brand Square D
SKU BGA260504
Select Item Condition
Earn 986 SuperPoints
  • 50A
  • 2 Pole
  • I-Line

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Square D BGA260504 - 50A 2 Pole Molded Case Circuit Breaker

Square D BGA260504 - 50A 2 Pole Molded Case Circuit Breaker

New

$986.00 In Stock

Quantity

Similar Items

Description

Designed for robust power distribution, this 50A PowerPacT B-Frame circuit breaker delivers reliable thermal-magnetic overcurrent protection. The unit features an I-Line mounting style with a phase BC connection, allowing it to install into Square D I-Line panelboards. It is a substitute for the legacy FA26050BC. Boasting a 35 kAIC rating at 480V, it provides strong current-limiting performance and includes fixed LI protection functions.

Specifications

Key specifications
Brand Square D
Series BGA
Amperage 50A
Poles 2
Mounting Style I-Line
Voltage 208Y/120VAC, 240VAC, 480Y/277VAC, 480VAC, 600Y/347VAC, 250VDC
Phase 1
AIC Rating 65kA @ 208Y/120VAC, 65kA @ 240VAC, 35kA @ 480Y/277VAC, 35kA @ 480VAC, 18kA @ 600Y/347VAC, 20kA @ 250VDC
Fit and installation
Frame Type BGA
Terminal Type Lugs
For Use With Square D I-Line Panelboards, Square D I-Line Switchboards
Wire Gauge 14-2/0 AWG (Al/Cu)
Max Wire 2/0 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Rotary Handle
Accessories None included
Standards CSA C22.2 No 5, EN/IEC 60947-2, NEMA AB 1, UL 489
Approval CCC, CE, CSA, EAC, IEC, NOM, UL
Temp Rating -25C to 70C
Construction Features HACR Rated, Phase Connection BC

Product FAQs

7 answers
What panelboards accept the BGA260504 circuit breaker?

This breaker mounts directly into Square D I-Line panelboards and switchboards. It utilizes a plug-on I-Line connection on the line side and mechanical lugs on the load side.

Can I use the BGA260504 to replace legacy F-frame breakers?

Yes, the PowerPacT B-frame is the modern replacement for legacy Square D FA and FH series breakers. It maintains the same 1.5-inch per pole width, allowing direct substitution in I-Line panels without requiring blank fillers.

What does the 4 at the end of the BGA260504 catalog number signify?

The 4 indicates the specific phase connection for the I-Line bus. For this 2-pole breaker, it specifies a BC phase connection.

What interrupting capacity does the G rating provide on this B-frame breaker?

The G performance level delivers 65 kAIC at 240VAC, 35 kAIC at 480VAC, and 18 kAIC at 600VAC. It also carries a 20 kAIC rating for 250VDC systems.

What is the required lug torque for the BGA260504 terminals?

The load-side mechanical lugs should be torqued to 31.9 to 38.9 lb-in for 14 to 10 AWG wire, and 44.3 to 54.9 lb-in for 8 to 2/0 AWG aluminum or copper wire.

How does the thermal-magnetic trip unit operate on this 50A breaker?

The breaker uses a fixed thermal element for long-time overload protection and a fixed magnetic element for instantaneous short-circuit protection. The dual-break rotating contacts also help reduce peak let-through current during a fault.

Is the BGA260504 HACR rated?

Yes, this PowerPacT B-frame circuit breaker is HACR rated, making it suitable for use with heating, air conditioning, and refrigeration equipment.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.