Square D JLA36250U31X Molded Case Circuit Breaker

  • 250A
  • 3 Pole
  • I-Line
Square D JLA36250U31X
Molded Case Circuit Breaker
Brand Square D
SKU JLA36250U31X
Select Item Condition
Earn 6960 SuperPoints
  • 250A
  • 3 Pole
  • I-Line

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Square D JLA36250U31X - 250A 3 Pole Molded Case Circuit Breaker

New

$6,960.00 In Stock

Quantity

Description

The JLA36250U31X is a 250A, 3-pole MCCB from Square D's PowerPacT J-Frame series. It mounts into standard I-Line panelboards and switchboards. This breaker replaces legacy KC36250 K-Frame units. It features an I-Line connection and includes AL250JD load lugs for 3/0 AWG to 350 kcmil wire. Equipped with a Micrologic 3.2 electronic trip unit, it provides adjustable LI settings. It delivers a 100 kAIC rating at 480VAC and true RMS sensing.

Specifications

Key specifications
Brand Square D
Part Number JLA36250U31X
Series JLA
Amperage 250A
Poles 3
Mounting Style I-Line
Voltage 240VAC, 480VAC, 600VAC
Phase 3
AIC Rating 125kA @ 240VAC, 100kA @ 480VAC, 50kA @ 600VAC
Electrical ratings
Amperage Range 70-250A
Fit and installation
Frame Type J
Terminal Type Lugs
For Use With Square D I-Line Panelboards, I-Line Switchboards
Wire Gauge 3/0 AWG - 350 kcmil (Al/Cu)
Max Wire 350 kcmil
Min Wire 3/0 AWG
Protection and operation
Trip Technology Electronic Trip
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Adjustable
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Communication Module
Accessories Load Side Lugs (AL250JD)
Standards CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, NOM-003-SCFI-2000, UL 489
Approval CE, CSA, IEC, NOM, UL, UKCA
Temp Rating -25C to 70C
Construction Features Current Limiting, HACR Rated, Visual Trip Indicator, Reverse Feed, Mercury Free, PVC Free, True RMS Sensing

Product FAQs

9 answers
What panels are compatible with the JLA36250U31X?

This plug-in breaker is designed exclusively for Square D I-Line panelboards and switchboards. It mounts directly onto the bus stack and is not compatible with standard load centers, NQB panels, or unit-mount applications.

How much mounting space does this J-frame breaker require on an I-Line bus?

As a three-pole J-frame circuit breaker, it occupies 4.5 inches of vertical mounting space on the I-Line bus stack, requiring 1.5 inches per pole.

What does the U31X signify in the catalog number?

In the Square D PowerPacT nomenclature, U31X indicates the inclusion of a standard Micrologic 3.2 electronic trip unit. This specific module provides adjustable Long-Time and Instantaneous (LI) protection without advanced communication features.

What wire sizes and materials are accepted by the standard lugs?

The factory-installed mechanical lugs safely accept either aluminum or copper conductors ranging from 3/0 AWG to 350 kcmil. Proper torque is required per the manufacturer label to ensure a secure, code-compliant connection.

What is the standard replacement lug kit for the JLA36250U31X?

If the original terminals are damaged or lost, the correct factory replacement mechanical lug kit is part number AL250JD, which is the standard set for 250A PowerPacT J-frame breakers.

Can the JLA36250U31X be applied at 100 percent of its continuous current rating?

No. Like most standard molded case circuit breakers, it is rated for 80 percent continuous use per the National Electrical Code. Continuous loads must not exceed 200 amps (80 percent of its 250A rating) for periods of three hours or longer.

How is this breaker mechanically secured into the panelboard?

Installers use a flat-blade screwdriver in the mounting bracket notch to lever and fully seat the plug-in jaws onto the I-Line bus. Once seated, it is firmly secured using the built-in captive retaining screw fastened directly to the panelboard backpan.

Can this circuit breaker be used in direct current (DC) applications?

No. Because it is equipped with a Micrologic solid-state electronic trip unit, it is rated strictly for alternating current (AC) systems up to 600VAC. It cannot be used to protect DC circuits.

Does the Micrologic 3.2 trip unit feature local energy metering?

No. The standard Micrologic 3.2 trip unit provides robust electronic overcurrent protection but does not include the integrated ammeter, LCD display, or energy monitoring capabilities found on the advanced A or E series MicroLogic units.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.