Built for demanding industrial applications, the PJA36060U44A is a 600A, 3-pole electronic trip MCCB from the Square D PowerPacT P-Frame series. Designed with an I-Line plug-on connection, it mounts into Square D I-Line panelboards and serves as a replacement for legacy MA36060 and MH36060 breakers. The included Micrologic 6.0A trip unit offers adjustable long-time, short-time, instantaneous, and ground fault (LSIG) protection alongside true RMS sensing.
CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, NOM-003-SCFI-2000, UL 489
Approval
CE, CSA, IEC, NOM, UL
Temp Rating
-25C to 70C
Construction Features
HACR Rated, True RMS Sensing, 80% Rated
Product FAQs
7 answers
What panelboards are compatible with the PJA36060U44A circuit breaker?
This I-Line plug-on circuit breaker is designed exclusively for use in Square D I-Line panelboards and switchboards. It cannot be installed in standard bolt-on panels or residential load centers.
Can the PJA36060U44A replace older Square D circuit breakers?
Yes, this PowerPacT P-Frame breaker serves as a modern replacement for legacy Square D MA36060 and MH36060 I-Line circuit breakers.
What specific trip unit is included with the PJA36060U44A?
This breaker is equipped with a Micrologic 6.0A electronic trip unit. The A designates an integrated ammeter for current monitoring, while providing adjustable Long-time, Short-time, Instantaneous, and Ground-fault (LSIG) protection.
How many conductors can be terminated on the load side of the PJA36060U44A?
The load side lugs are designed to accept three separate conductors per phase, accommodating wire sizes from 3/0 AWG up to 500 kcmil in either aluminum or copper.
Is the PJA36060U44A rated for 100 percent continuous operation?
No, this breaker carries a standard 80 percent continuous current rating. For a 600A frame, continuous loads must not exceed 480 amps to comply with standard electrical codes.
How is the PJA36060U44A physically installed into a system?
It features an I-Line plug-on connection for the line side, which engages directly with the buswork of an I-Line panelboard or switchboard. The load side utilizes mechanical lugs for standard cable termination.
How does the ground-fault protection function on this breaker?
The integrated ground-fault protection, indicated by the G in the LSIG designation, provides adjustable pickup and delay settings. This allows electricians to fine-tune the breaker for precise system coordination and equipment protection.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.