Part of the PowerPacT Q-Frame lineup, the Square D QDA221503 provides thermal-magnetic protection for commercial and industrial systems. This 150A, 2-pole breaker handles demanding power distribution with long-time and instantaneous (LI) trip functions. Engineered for seamless integration, it mounts into Square D I-Line panelboards and switchboards. It features a BA phase connection and replaces legacy Q221503 models. Rated 25kAIC at 240VAC, it includes a Visi-Trip indicator.
CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489
Approval
CSA, IEC, NOM, UL
Temp Rating
-25C to 70C
Construction Features
HACR Rated, Visual Trip Indicator, Non-Interchangeable Trip, Phase Connection BA
Product FAQs
9 answers
What panelboards are compatible with the QDA221503?
This breaker is designed for use in Square D I-Line panelboards and switchboards. It features an I-Line style plug-in connection and is not compatible with QO or Homeline load centers.
Can I use the QDA221503 to replace an older Q2 Series breaker?
Yes, the PowerPacT Q-frame circuit breaker is a direct replacement for legacy Q2 Series devices in I-Line panelboards.
What does the 3 at the end of the QDA221503 catalog number mean?
In Square D PowerPacT Q-frame nomenclature, the 3 suffix on a 2-pole I-Line breaker indicates a BA phase connection on the bus.
Are the trip settings adjustable on the QDA221503?
No, the QDA221503 features a thermal-magnetic trip unit with fixed thermal (long-time) and fixed magnetic (instantaneous) settings.
What is the interrupting rating of the QDA221503 compared to other Q-frame breakers?
The QDA221503 has an interrupting rating of 25 kAIC at 240V. If your system requires a different rating, the QBA series offers 10 kAIC, the QGA offers 65 kAIC, and the QJA offers 100 kAIC.
What is the recommended lug torque for the QDA221503?
The line and load lugs should be torqued to 248 lb-in (28 N.m). The lugs accept 4 AWG to 300 kcmil aluminum or copper wire.
What is the wire stripping length for the lugs on this breaker?
The recommended power wire stripping length for the lugs is 0.87 inches (22 mm).
What is the difference between the QDA221503 and the QBA221503?
The difference is the interrupting rating. The QDA221503 is rated for 25 kAIC at 240V, while the QBA221503 is rated for 10 kAIC at 240V. Both share the same 150A rating, 2-pole configuration, and BA phase connection.
How can I manually test the tripping mechanism on the QDA221503?
You can manually test the mechanism using the integral push-to-trip button located on the front cover of the breaker. This allows you to verify the mechanical operation of the trip unit safely.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 6 reviews.