Square D QJL32110 Molded Case Circuit Breaker

  • 110A
  • 3 Pole
  • Unit Mount
Square D QJL32110
Molded Case Circuit Breaker
Brand Square D
SKU QJL32110
Select Item Condition
Earn 2102 SuperPoints
  • 110A
  • 3 Pole
  • Unit Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Square D QJL32110 - 110A 3 Pole Molded Case Circuit Breaker

New

$2,102.50 In Stock

Quantity

Description

Built to protect circuits against overloads and short circuits, the Square D QJL32110 is a 110A, 3-pole molded case circuit breaker rated for 208Y/120VAC and 240VAC. It provides 100kA interrupting capacity at both voltages. The QJL series breaker has a Q Frames physical frame and unit mounting. Its fixed thermal-magnetic trip provides long-time and instantaneous protection. Approvals include CSA, IEC, NOM and UL.

Specifications

Key specifications
Brand Square D
Part Number QJL32110
Series QJL
Amperage 110A
Poles 3
Mounting Style Unit Mount
Voltage 208Y/120VAC, 240VAC
Phase 3
AIC Rating 100kA @ 208Y/120VAC, 100kA @ 240VAC
Fit and installation
Frame Type QJL
Terminal Type Box Lugs
For Use With Square D QO Load Centers, NQ Panelboards, NQOD Panelboards
Wire Gauge 4 AWG-300 kcmil
Max Wire 300 kcmil
Min Wire 4 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Alarm Switch, Auxiliary Switch, Padlock Attachment, Shunt Trip, Undervoltage Release
Accessories Load Side Lugs
Standards CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489
Approval CSA, IEC, NOM, UL
Temp Rating 40C to 70C
Construction Features HACR Rated, Non-Interchangeable Trip

Product FAQs

9 answers
How should I use the 110A rating when selecting the Square D QJL32110?

The 110A rating is the breaker's rated current. Use it when evaluating the circuit load and conductor overcurrent protection, rather than treating the instantaneous trip function as the circuit's current rating.

What circuit voltages is this breaker rated for?

The breaker is rated for 208Y/120VAC and 240VAC. Match the circuit voltage to one of these ratings when selecting it for an AC installation.

How do I check whether its interrupting rating is sufficient?

Its interrupting rating is 100kA at 208Y/120VAC and 100kA at 240VAC. Compare the available fault current at the installation point with the rating for the circuit voltage; the available fault current must not exceed that interrupting rating.

What conductor sizes can I terminate in the box lugs?

The box lugs accept conductors from 4 AWG through 300 kcmil. Check both the conductor's ampacity and its size when selecting wiring, since acceptance by the lug does not by itself determine suitable conductor ampacity.

How are the three poles used, and does the breaker have a neutral connection?

Use the three poles for the phase conductors of a three-phase circuit. A neutral connection is not applicable to this breaker, so account for any circuit neutral separately in the wiring layout.

What dimensions and mounting style should I account for during installation planning?

The breaker uses unit mounting and measures 6.47 in high, 4.50 in wide, and 3.93 in deep. Use these body dimensions and the mounting style when planning the mechanical layout and installation space.

What does the HACR rating mean for equipment protection?

HACR refers to heating, air-conditioning, and refrigeration applications. The HACR rating is relevant when equipment requirements call for this type of circuit breaker; also check the circuit's current, voltage, and available fault current.

Which circuit breaker standards should I check against project requirements?

The applicable standards are CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, and UL 489. Use these when reviewing project requirements for molded case circuit breaker construction and performance.

Can I adjust the thermal or magnetic trip settings?

The thermal and magnetic trip settings are fixed and cannot be adjusted. The thermal function provides long-time overload protection, while the magnetic function provides instantaneous short-circuit protection. Use fixed trip behavior when planning protection coordination.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.