Built for circuit protection, the Square D QJP22200TP molded case circuit breaker uses fixed thermal and magnetic tripping. Rated 200A and 240VAC, it has 2 poles and 100kAIC interrupting capacity at 240V. The single-phase PowerPacT QJP series breaker has a Q frame, bolt-on mounting and load side lug connection. Its thermal magnetic trip provides long-time and instantaneous protection. It has UL approval.
How should I use the Square D QJP22200TP's 200A rating when selecting it?
The 200A rating is the breaker's rated current. Select it when the circuit design calls for 200A overcurrent protection, coordinating the breaker rating with the load and conductor ampacity.
How does the 240VAC rating guide voltage selection?
The breaker is rated for 240VAC. Check the circuit's AC voltage when selecting it, and keep the application within that voltage rating.
What does the 100kAIC interrupting rating mean for fault-current selection?
At 240V, the breaker has a 100kAIC interrupting rating. Compare that rating with the available fault current at the installation point; the available fault current must not exceed the interrupting rating.
When should I select the 2-pole, single-phase configuration?
Select this configuration when the circuit design requires two-pole protection on a single-phase circuit. Use both the pole count and phase arrangement when choosing the breaker.
How does the thermal-magnetic trip protect the circuit?
The thermal element provides long-time protection against sustained overloads, while the magnetic element provides instantaneous response to short-circuit current. This combines overload and short-circuit protection in one breaker.
Can I adjust the thermal or magnetic trip settings?
Both the thermal and magnetic trip settings are fixed. Choose this breaker when fixed trip settings suit the circuit's protection requirements rather than an application requiring field-adjustable settings.
What does bolt-on mounting mean for installation?
Bolt-on mounting uses bolted connections to secure the breaker. Plan installation around fastening those connections rather than a plug-in mounting operation.
How are the outgoing load conductors connected?
The load-side connection uses lugs to terminate the outgoing conductors. Plan the load wiring for lug termination and secure the conductors in those terminals during installation.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.