Built for circuit protection, the Square D RGF36120U41A molded case circuit breaker is rated 1200A with 3 poles. Interrupting ratings are 65kA at 240VAC, 35kA at 480VAC and 18kA at 600VAC. This PowerPacT RGF R-frame breaker uses unit mounting and a busbar connection. Its adjustable electronic trip provides long-time and instantaneous protection. Approvals include CE, CSA, IEC, NOM and UL.
CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489
Approval
CE, CSA, IEC, NOM, UL
Temp Rating
-25C to 70C
Construction Features
HACR Rated, 80% Rated
Product FAQs
8 answers
How should I account for the Square D RGF36120U41A's 1200A rating and 80% rating?
This 1200A breaker is 80% rated. Size continuous loads using the 80% loading limit rather than treating 1200A as its continuous-load allowance.
How do I select this breaker for system voltage and available fault current?
Its interrupting ratings are 65kA at 240VAC, 35kA at 480VAC and 18kA at 600VAC. Select the rating corresponding to the system voltage and verify that it meets or exceeds the available fault current at the installation point.
What protection does the adjustable LI electronic trip offer?
The LI electronic trip provides adjustable long-time and instantaneous protection. Long-time protection addresses sustained overcurrent, while instantaneous protection responds to high fault current without intentional delay. Set the trip to suit the protected circuit and coordination requirements.
What mounting style and dimensions should I plan around?
This unit-mount breaker measures 16.24 in high, 16.53 in wide and 14.49 in deep. Use those dimensions when planning the mounting layout and physical space for installation.
What type of electrical termination should I plan for?
The terminal type is busbar connection. Plan the electrical connection layout around busbar terminations.
What does the HACR rating mean for application selection?
The HACR rating applies to heating, air-conditioning and refrigeration applications. Use it when selecting circuit protection for an application that calls for a HACR-rated breaker.
What temperature range should I consider when planning the installation?
The temperature rating is -25C to 70C. Check the expected temperature at the breaker location against this range when assessing the installation environment.
How do the three poles affect phase-conductor routing?
The Square D RGF36120U41A has three poles and a three-phase configuration. Route each phase conductor through its corresponding pole so all three phases are interrupted together when the breaker opens.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.