Part of the PowerPacT R-Frame series, the Square D RGF36160U41A delivers 1600A of continuous current for demanding commercial and industrial applications. It utilizes a unit mount design with busbar connections, making it ideal for integration into Square D QED switchboards and Model 6 Motor Control Centers. Equipped with a Micrologic 3.0A electronic trip unit, this 80% rated breaker provides adjustable long-time and instantaneous (LI) protection alongside true RMS sensing.
CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489
Approval
CE, CSA, IEC, NOM, UL
Temp Rating
-25C to 70C
Construction Features
HACR Rated, 80% Rated, True RMS Sensing, Ammeter
Product FAQs
8 answers
What equipment is the Square D RGF36160U41A circuit breaker designed to be installed in?
This 1600A PowerPacT R-frame breaker is primarily used in Square D QED switchboards and Model 6 motor control centers.
What size wire is accepted by the terminals on the RGF36160U41A?
The standard lugs for this breaker accept aluminum or copper wire ranging from 3/0 AWG to 750 kcmil.
What specific trip unit is included with the RGF36160U41A?
This breaker features a Micrologic 3.0A electronic trip unit, which provides adjustable long-time and instantaneous (LI) protection along with integrated ammeter capabilities.
How does the RGF36160U41A mount into an electrical panel?
It is a unit-mount, or bolt-on, breaker that uses a feed-thru busbar connection rather than an I-Line plug-on connection.
What does the U41A in the RGF36160U41A catalog number indicate?
The U41A suffix specifies that the breaker is equipped with a Micrologic 3.0A electronic trip unit, featuring long-time and instantaneous (LI) trip functions.
Does the RGF36160U41A provide ground fault protection?
No. Despite some general descriptions, the U41A suffix specifically indicates a Micrologic 3.0A trip unit, which only provides long-time and instantaneous (LI) trip functions. It does not include ground fault protection.
Can the trip unit on the RGF36160U41A be upgraded or changed in the field?
Yes, PowerPacT R-frame breakers with Micrologic trip units allow the trip unit to be interchanged in the field, providing flexibility if your protection requirements change.
Is the RGF36160U41A rated for 80 percent or 100 percent continuous current?
This specific model is standard rated for 80 percent continuous current.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.