| Brand | ABB / General Electric |
|---|---|
| Part Number | TJK436225WL |
| Series | TJK |
| Amperage | 225A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC, 20kA @ 500VDC |
| Frame Type | TJK |
|---|---|
| Terminal Type | Lugs |
| For Use With | Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | (1) 6 AWG-600 kcmil (Cu/Al) or (2) 2/0 AWG-250 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs (TCAL43) |
| Standards | CSA C22.2 No. 5.1, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TJK436225WL-R |
| Series | TJK |
| Amperage | 225A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC, 20kA @ 500VDC |
| Frame Type | TJK |
|---|---|
| Terminal Type | Lugs |
| For Use With | Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | (1) 6 AWG-600 kcmil (Cu/Al) or (2) 2/0 AWG-250 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs (TCAL43) |
| Standards | CSA C22.2 No. 5.1, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit |
ABB / General ElectricTJK436250WL
ABB / General ElectricTJK636250WL
ABB / General ElectricTJK436200WL
ABB / General ElectricTJK436300WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TJK436225WL |
| Series | TJK |
| Amperage | 225A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC, 20kA @ 500VDC |
| Frame Type | TJK |
|---|---|
| Terminal Type | Lugs |
| For Use With | Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | (1) 6 AWG-600 kcmil (Cu/Al) or (2) 2/0 AWG-250 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs (TCAL43) |
| Standards | CSA C22.2 No. 5.1, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit |
The WL suffix designates that the circuit breaker is supplied from the factory with both line and load side lugs installed, making it ready for immediate wire termination.
Yes, the thermal-magnetic trip unit features an adjustable magnetic trip function. This allows you to modify the instantaneous short-circuit response, while the thermal overload protection remains fixed.
No. GE J600 line breakers with interchangeable trip units, including the TJK and THJK frames, are not suitable for reverse feed applications. Power must be supplied to the designated line terminals.
Yes, this model is rated for DC applications. It provides a 20kA interrupting capacity at both 250VDC and 500VDC.
Both frames belong to the GE J600 line and share the exact same physical dimensions and mounting footprint. The primary difference is that the THJK series offers a higher interrupting capacity (AIC) than the standard TJK series.
The standard lugs on this breaker can accommodate either a single conductor ranging from 6 AWG to 600 kcmil, or two separate conductors ranging from 2/0 AWG to 250 kcmil per phase. Both copper and aluminum wires are supported.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.