Eaton / Cutler-HammerGHB3035S1
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3035 |
| Series | GHB |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line 2 (PRL2) Panelboards, Eaton Pow-R-Line 3 (PRL3) Panelboards, Series C Panelboards |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Alarm Switch, Auxiliary Switch, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3035-R |
| Series | GHB |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line 2 (PRL2) Panelboards, Eaton Pow-R-Line 3 (PRL3) Panelboards, Series C Panelboards |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Alarm Switch, Auxiliary Switch, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Eaton / Cutler-HammerGHB3035S1
Eaton / Cutler-HammerGHB3040S1
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3035-R |
| Series | GHB |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line 2 (PRL2) Panelboards, Eaton Pow-R-Line 3 (PRL3) Panelboards, Series C Panelboards |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Alarm Switch, Auxiliary Switch, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
This G-Frame breaker installs natively into Eaton Pow-R-Line 2 (PRL2), Pow-R-Line 3 (PRL3), and Series C panelboards. It is also completely compatible with older Cutler-Hammer and Westinghouse panelboards designed for GHB branch breakers.
Yes. Eaton acquired the Cutler-Hammer and Westinghouse electrical distribution divisions. The modern Eaton GHB3035 is an authentic, direct replacement for legacy Westinghouse and Cutler-Hammer breakers carrying the exact same catalog number.
As a bolt-on breaker, it fastens directly to the panelboard busbar using mechanical hardware on the line side. This provides a more secure, vibration-resistant electrical connection compared to plug-on breakers, which is frequently required in commercial and industrial specifications.
The factory-installed pressure lugs are dual-rated for either copper (Cu) or aluminum (Al) conductors. They accept wire sizes ranging from 10 AWG up to 1/0 AWG, providing flexibility for various branch circuit load requirements.
The thermal-magnetic (LI) trip mechanism provides two essential layers of protection. The fixed thermal element uses a bimetallic strip to safely disconnect prolonged overloads, while the fixed magnetic element responds immediately to high-fault short circuits.
Yes. Beyond its primary commercial 480Y/277VAC rating, this model is fully rated for 125/250VDC applications with a 14kA interrupting capacity, making it suitable for specialized DC control or battery systems.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.