ABB / General ElectricSGDA22AT0400
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | SGDA32AT0400 |
| Series | SGDA |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 1) 8 AWG-600 kcmil (Al/Cu) or 2) 2/0 AWG-500 kcmil (Al/Cu) |
| Max Wire | 600 kcmil (Single) or 500 kcmil (Double) |
| Min Wire | 8 AWG (Single) or 2/0 AWG (Double) |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Undervoltage Release, Auxiliary Switch, Lug Kits |
|---|---|
| Accessories | Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, IEC, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Current Limiting, Digital RMS Sensing, Interchangeable Rating Plug, True RMS Sensing |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | SGDA32AT0400-R |
| Series | SGDA |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 1) 8 AWG-600 kcmil (Al/Cu) or 2) 2/0 AWG-500 kcmil (Al/Cu) |
| Max Wire | 600 kcmil (Single) or 500 kcmil (Double) |
| Min Wire | 8 AWG (Single) or 2/0 AWG (Double) |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Undervoltage Release, Auxiliary Switch, Lug Kits |
|---|---|
| Accessories | Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, IEC, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Current Limiting, Digital RMS Sensing, Interchangeable Rating Plug, True RMS Sensing |
ABB / General ElectricSGDA22AT0400
ABB / General ElectricSGLC3604L4XX
ABB / General ElectricSGLC3604L5XX
ABB / General ElectricSGLC3604L7XX
| Brand | ABB / General Electric |
|---|---|
| Part Number | SGDA32AT0400-R |
| Series | SGDA |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 1) 8 AWG-600 kcmil (Al/Cu) or 2) 2/0 AWG-500 kcmil (Al/Cu) |
| Max Wire | 600 kcmil (Single) or 500 kcmil (Double) |
| Min Wire | 8 AWG (Single) or 2/0 AWG (Double) |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Undervoltage Release, Auxiliary Switch, Lug Kits |
|---|---|
| Accessories | Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, IEC, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Current Limiting, Digital RMS Sensing, Interchangeable Rating Plug, True RMS Sensing |
Yes, this breaker has no line or load markings and can be reverse fed, allowing power connections to either the top or bottom terminals.
Yes, all GE Spectra RMS electronic trip breakers require a field-installable, front-mounted rating plug to establish the continuous ampere rating.
You must use an SRPG400A series rating plug, such as the SRPG400A250 or SRPG400A400, to configure the trip point for this specific breaker.
Yes, this model carries a HACR rating, making it approved for use with commercial heating, air conditioning, and refrigeration equipment.
The solid-state RMS sensing technology uses digital sampling to determine the true RMS value of both sinusoidal and non-sinusoidal currents, providing accurate protection in systems with harmonics.
The short-time function delays the trip during a fault, allowing downstream protective devices like fuses or starter overloads enough time to clear the fault before the main breaker opens.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.