ABB / General ElectricTHED136035
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134035-R |
| Series | TED |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Load Lugs (TCAL12) |
| Standards | UL 489, NEMA AB 1, CSA C22.2 No. 5 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free, HID Rated |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134035-R |
| Series | TED |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Load Lugs (TCAL12) |
| Standards | UL 489, NEMA AB 1, CSA C22.2 No. 5 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free, HID Rated |
ABB / General ElectricTHED136035
ABB / General ElectricTED134030
ABB / General ElectricTED134040
ABB / General ElectricTED134060
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134035-R |
| Series | TED |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Load Lugs (TCAL12) |
| Standards | UL 489, NEMA AB 1, CSA C22.2 No. 5 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free, HID Rated |
ABB acquired GE Industrial Solutions in 2018. Depending on the manufacturing date, this TED-frame breaker may feature either GE or ABB branding, but the physical dimensions, fit, and electrical specifications remain identical.
This E-frame breaker is designed to bolt into legacy GE A-Series and Spectra Series panelboards. It requires the appropriate mounting hardware or strap kits specific to your panel interior.
The GE TEFP1 filler plate is used to safely cover unused TED-frame breaker knockouts in compatible panelboards.
Yes. Because it is a standard thermal-magnetic breaker without specific line and load directional markings, it is suitable for reverse feed applications.
The LI designation means the breaker provides Long-Time (thermal) overload protection and Instantaneous (magnetic) short-circuit protection. Both trip settings are fixed on this model.
The TED series belongs to the GE E150 frame family, which has a maximum continuous current rating of 150 amps.
It features standard mechanical lugs rated for both copper and aluminum conductors. Ensure conductors are sized within the 14-3 AWG (Cu) or 12-1 AWG (Al) range and torqued to the manufacturer specifications printed on the breaker.
Yes, it is rated for DC applications up to 500VDC with a 10kA interrupting capacity. When used at 500VDC, specific series wiring of the poles is required per the manufacturer guidelines.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.