Skip to main content
Expedited shipping available at checkout

ABB / General Electric TKMA31200WL Molded Case Circuit Breaker

  • 1200A
  • 3 Pole
  • Unit Mount
ABB / General Electric TKMA31200WL
Molded Case Circuit Breaker
Brand ABB / General Electric
SKU TKMA31200WL
Select Item Condition
Earn 4351 SuperPoints
  • 1200A
  • 3 Pole
  • Unit Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.

ABB / General Electric TKMA31200WL - 1200A 3 Pole Molded Case Circuit Breaker

New

$4,351.95 Check Stock

Quantity

Similar Items

Description

Designed for standalone enclosure mounting, the GE TKMA31200WL delivers 1200A of thermal-magnetic protection. Unlike standard bolt-on models, this unit-mount (feed-thru) K-frame breaker comes equipped with line and load lugs (TCAL121) for flexible installation in switchboards and motor control centers. It features an interchangeable trip unit with long-time and instantaneous (LI) functions. Rated at 42kAIC at 240VAC, it provides robust overcurrent defense for demanding industrial applications.

Specifications

Key specifications
Brand ABB / General Electric
Part Number TKMA31200WL
Series TKMA
Amperage 1200A
Poles 3
Mounting Style Unit Mount
Voltage 240VAC, 480VAC, 600VAC, 250VDC
Phase 3
AIC Rating 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC
Fit and installation
Frame Type TKM
Terminal Type Lugs
For Use With GE Switchboards, Motor Control Centers, Enclosures
Wire Gauge (4) 250-350 kcmil (Cu) or (4) 250-500 kcmil (Al)
Max Wire 500 kcmil
Min Wire 250 kcmil
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Adjustable Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch
Accessories Line and Load Lugs (TCAL121)
Standards UL 489, NEMA AB-1, CSA C22.2 No. 5
Approval CSA, UL
Temp Rating 40C
Construction Features Interchangeable Trip Unit, Reverse Feed

Product FAQs

9 answers
What does the "WL" suffix in the TKMA31200WL catalog number indicate?

The "WL" suffix designates that the breaker is supplied with factory-installed line and load lugs. GE circuit breaker models ordered without this suffix typically do not include line-side lugs.

What type of equipment is the TKMA31200WL designed to fit?

This legacy K-Frame molded case circuit breaker is engineered for unit-mount installations in General Electric switchboards, motor control centers (MCCs), and individual enclosures.

What is the conductor capacity for the standard lugs on this 1200A breaker?

The included lugs are configured to accept four wires per phase. They accommodate wire sizes ranging from (4) 250 to 350 kcmil for copper (Cu) conductors or (4) 250 to 500 kcmil for aluminum (Al) conductors.

Are the trip settings on the TKMA31200WL adjustable?

Yes, this breaker uses an interchangeable thermal-magnetic trip unit featuring a fixed thermal element for long-time overcurrents and an adjustable magnetic element to dial in the instantaneous trip threshold.

What is the difference between GE TKMA and THKMA circuit breakers?

The TKMA series features a standard interrupting capacity, rated at 30kAIC at 480VAC. The THKMA series is the high-interrupting capacity version of the same K-Frame, which bumps the interrupting rating to 35kAIC or higher at 480VAC.

Can the TKMA31200WL circuit breaker be reverse-fed?

Yes, this thermal-magnetic K-Frame breaker is rated for reverse-feed applications. Installers must still verify that the specific panelboard or enclosure is listed to accept reverse-fed breakers before installation.

Is the trip unit on this K-Frame breaker permanently fixed to the frame?

No, the TKMA31200WL features an interchangeable trip unit design. This allows the thermal-magnetic module to be replaced without removing the entire circuit breaker frame from the bus structure.

Does this breaker provide ground fault protection?

No, the TKMA31200WL uses an LI (Long-Time and Instantaneous) trip unit. It provides standard thermal overload and magnetic short-circuit protection, but does not include integrated ground fault (G) protection capabilities.

What are the primary safety requirements when replacing this 1200A MCCB?

Installation must be performed by a qualified electrician. Always completely de-energize, lock out, and tag out (LOTO) the switchgear power feed and verify zero voltage with a properly rated meter before accessing any busbars or terminals.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.