Eaton / Cutler-HammerFS320100A
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | FS |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC, 14kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | FS |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Series C Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 14-1/0 AWG |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release |
|---|---|
| Accessories | Includes Line and Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Factory Sealed |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | FS |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC, 14kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | FS |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Series C Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 14-1/0 AWG |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release |
|---|---|
| Accessories | Includes Line and Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Factory Sealed |
Eaton / Cutler-HammerFS320100A
Eaton / Cutler-HammerFS320090A
Eaton / Cutler-HammerFS340090A
Eaton / Cutler-HammerFS360090A
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | FS |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC, 14kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | FS |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Series C Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 14-1/0 AWG |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release |
|---|---|
| Accessories | Includes Line and Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Factory Sealed |
This Series C F-Frame breaker is designed to bolt onto Eaton panelboards, switchboards, motor control centers, and industrial enclosures.
The included line and load lugs accept copper or aluminum conductors ranging from 14 AWG to 1/0 AWG. Ensure proper torque specifications are followed during installation.
As a bolt-on molded case circuit breaker, it mounts directly to the bus of compatible Eaton Series C panelboards. Individual enclosure mounting may require a separate pre-drilled mounting panel.
No, this breaker is equipped with a fixed thermal and fixed magnetic trip unit. The long-time and instantaneous (LI) trip functions are factory set and cannot be modified.
Because it utilizes a thermal-magnetic trip unit rather than an electronic trip unit, it can effectively protect both alternating current and direct current circuits, including 250VDC systems.
The FS340100A delivers 14kAIC at 480VAC. If your fault current calculations require a higher rating in the same F-Frame footprint, you will need to source an FD, HFD, or FDC series breaker.
Always verify that the panelboard or switchboard is fully de-energized and locked out before installing the breaker. Verify that the available fault current does not exceed the 14kAIC rating at 480VAC before energizing the circuit.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.