Eaton / Cutler-HammerBAB3030HS
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3030H |
| Series | BAB |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards, Challenger Panelboards |
| Wire Gauge | 14-8 AWG (Al/Cu) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Standards | HACR, UL 489, CSA C22.2 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3030H-R |
| Series | BAB |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards, Challenger Panelboards |
| Wire Gauge | 14-8 AWG (Al/Cu) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Standards | HACR, UL 489, CSA C22.2 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Eaton / Cutler-HammerBAB3030HS
Eaton / Cutler-HammerBAB3035HS
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3030H-R |
| Series | BAB |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards, Challenger Panelboards |
| Wire Gauge | 14-8 AWG (Al/Cu) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Standards | HACR, UL 489, CSA C22.2 |
| Approval | CSA, UL |
| Temp Rating | 40C |
The BAB3030H is designed for use in Eaton Pow-R-Line panelboards, specifically models like the PRL1a and PRL1X. It is also compatible with legacy Cutler-Hammer, Westinghouse, Bryant, and Challenger bolt-on panelboards that accept Quicklag miniature breakers.
Yes, this 30A circuit breaker is HACR rated. This certification means it has been tested and approved to safely handle the specific inrush currents and operational demands of commercial HVACR equipment.
It features a bolt-on mounting design. The breaker physically bolts directly to the panelboard busbar using an extended tang line terminal. This provides a secure, vibration-resistant connection typically required in industrial and commercial applications.
Both are 30A, 3-pole Quicklag bolt-on circuit breakers with identical physical dimensions, but they differ in their short-circuit interrupting capacity. The BAB3030H has a 10 kAIC rating, while the QBHW3030H features a higher 22 kAIC rating at 240VAC.
Yes. Because Eaton acquired the Cutler-Hammer and Westinghouse distribution equipment lines, the current Eaton BAB3030H is a direct, UL-approved drop-in replacement for legacy breakers sharing the exact same BAB catalog number.
No. While both breaker types can sometimes be installed in the same overall Eaton Pow-R-Line enclosure, BAB and GHB breakers have different frame sizes and mounting requirements. They cannot be mixed on the exact same subchassis.
No, the BAB3030H is a standard thermal-magnetic circuit breaker that provides only overload and short-circuit protection. It does not include GFCI or AFCI safety circuitry. If ground fault protection is required, a QBGF or QBHGF series breaker must be used instead.
The BAB3030H features a fixed thermal-magnetic trip unit. This means the trip thresholds for both overload and short-circuit protection are factory calibrated and cannot be adjusted or swapped out in the field.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.