| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3030HS |
| Series | BAB |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Bryant Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Shunt Trip |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3030HS-R |
| Series | BAB |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Bryant Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Shunt Trip |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Eaton / Cutler-HammerBAB3035HS
Eaton / Cutler-HammerBAB3025HS
Eaton / Cutler-HammerBAB3040HS
Eaton / Cutler-HammerBAB3020HS
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3030HS |
| Series | BAB |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Bryant Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Shunt Trip |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
This bolt-on breaker mounts exclusively into Eaton Pow-R-Line, legacy Westinghouse, and Bryant panelboards designed for Quicklag BAB type breakers. It cannot be used in residential plug-on load centers like the Eaton BR or CH series.
Although it is a 3-pole breaker, the factory-installed shunt trip requires one extra pole space on the right side. You will need a total of four pole spaces in your panelboard to install this unit.
The HS suffix designates a factory-installed shunt trip module. This feature allows the breaker to be tripped remotely by applying an external control voltage, which is commonly used for emergency stops or fire alarm control panels.
The shunt trip includes non-polarity-sensitive wire leads. You must connect one lead to your control voltage source and route the other lead through a normally open contact, such as a momentary pushbutton or alarm relay, to complete the tripping circuit.
Yes. Eaton and Cutler-Hammer are the same brand. The current Eaton BAB3030HS is the direct, manufacturer-approved replacement for the legacy Cutler-Hammer version and features the exact same form factor and specifications.
Yes, this circuit breaker is HACR rated. It is fully approved for protecting heating, air conditioning, and refrigeration circuits that require HACR-certified overcurrent protection.
No. The shunt trip is strictly designed for remote manual tripping or interfacing with external control systems. It does not provide integral GFCI or AFCI safety protection.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.