Eaton / Cutler-HammerBAB3100HS
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3100H |
| Series | BAB |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3100H-R |
| Series | BAB |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Eaton / Cutler-HammerBAB3100HS
Eaton / Cutler-HammerBAB3090HS
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3100H |
| Series | BAB |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
This bolt-on breaker is designed for Eaton, Cutler-Hammer, and legacy Westinghouse commercial panelboards. It is specifically engineered to mount in Pow-R-Line series panels, including the PRL1a, PRL2a, PRL1X, and PRL2X models.
No. As a bolt-on industrial breaker, it physically screws into threaded panel busbars and will not fit in standard residential plug-on load centers, such as the Eaton BR or CH series.
Both series share the exact same physical dimensions and bolt-on mounting design for Pow-R-Line panels. The distinction is their short-circuit interrupting rating: the BAB series is rated for 10 kAIC at 240V, while the QBHW series is rated for 22 kAIC at 240V.
Yes, the BAB3100H carries an HACR (Heating, Air Conditioning, and Refrigeration) rating. It is fully approved to handle the inrush currents and motor-starting surges associated with HVAC equipment.
Yes. Following Eaton's acquisition of Cutler-Hammer, the BAB product line remained physically and electrically identical. Breakers stamped with either brand name are exact replacements for one another.
No. This unit is a standard thermal-magnetic breaker that provides essential protection against overloads and short circuits. It does not contain GFCI or AFCI circuitry. Ground fault protection in this bolt-on form factor requires the QBGF or QBHGF series breakers.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.