Eaton / Cutler-HammerJGS3125FAG
Quantity
New
Quantity
Eaton / Cutler-HammerJGS3125FAG
Eaton / Cutler-HammerJGS3150FAG
Eaton / Cutler-HammerJGS3175FAG
Eaton / Cutler-HammerJGS3200FAG
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | JGS3100FAG |
| Series | JGS |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 85kA @ 240VAC, 35kA @ 480VAC, 18kA @ 600VAC, 22kA @ 250VDC |
| Frame Type | JG |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Series G Panelboards, Switchboards, MCCs |
| Wire Gauge | 4 AWG - 350 kcmil (Al/Cu) |
| Max Wire | 350 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle, Terminal Shields |
|---|---|
| Accessories | Line and Load Lugs Included (TA250FJ), Mounting Hardware |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CCC, CE, CSA, IEC, KEMA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated |
The FAG suffix indicates that the breaker features a fixed thermal and adjustable magnetic trip unit, and it comes factory equipped with line and load terminals.
The S in the JGS prefix designates the standard interrupting capacity for the Series G JG frame, which provides a 35 kAIC rating at 480 VAC.
This JG frame breaker is designed for use in Eaton Series G panelboards, switchboards, and motor control centers, including compatible Allen-Bradley and Rockwell Automation enclosed controls.
Yes, this breaker comes factory equipped with standard line and load lugs, as indicated by the FAG suffix in the catalog number.
It features a thermal magnetic trip unit with a fixed thermal setting for long time overload protection and an adjustable magnetic setting for instantaneous short circuit protection.
No, the thermal overload setting is fixed at 100 amps. Only the magnetic instantaneous trip response is adjustable on this specific model.
Yes, this breaker is rated for up to 250 VDC with an interrupting capacity of 22 kAIC, making it suitable for specific direct current control circuits.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.