Eaton / Cutler-HammerCHFN115DF
Quantity
New
Quantity
Eaton / Cutler-HammerCHFN115DF
Eaton / Cutler-HammerCHFN120DF
Eaton / Cutler-HammerCHFAFGF115
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | CHFN115A1CS |
| Series | CHFN |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | CH |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Eaton CH Load Centers |
| Wire Gauge | 14-6 AWG |
| Max Wire | 6 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | Dual Function (AFCI/GFCI) |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | UL 489, UL 943, UL 1699, CSA C22.2 No. 5 |
| Approval | UL, CSA |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Self-Test, Visual Trip Indicator |
This breaker is designed specifically for Eaton CH series load centers. It mounts on a standard 3/4-inch space and cannot be installed in Eaton BR panels or load centers from other manufacturers.
No. This breaker features a pigtail neutral connection. The attached white pigtail wire connects directly to the panel neutral bar, allowing it to be installed in standard CH load centers that lack a plug-on neutral bus.
The white load neutral wire from the branch circuit must be terminated directly at the breaker lug marked for the load neutral. The breaker's coiled white pigtail wire is then routed and connected to the main neutral bar in the panel.
This breaker serves as a direct replacement for older Eaton CH series 15A dual function breakers, including the discontinued CHFAFGF115 catalog number.
It combines Arc Fault Circuit Interrupter (AFCI) and Ground Fault Circuit Interrupter (GFCI) technology in one unit. This provides protection against electrical fires caused by arcing faults as well as shock hazards from ground faults, meeting NEC requirements for areas like kitchens and laundry rooms.
After a trip, reset the breaker handle to the ON position. The trip code will be displayed via the LED for 30 patterns immediately after the reset. To access the code later, turn the breaker OFF, press and hold the TEST button, turn the breaker ON, and then release the TEST button.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.