Eaton / Cutler-HammerEGB3050FFG
Quantity
New
Quantity
Eaton / Cutler-HammerEGB3050FFG
Eaton / Cutler-HammerEGB3040FFG
Eaton / Cutler-HammerEGB3035FFG
Eaton / Cutler-HammerEGB3060FFG
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | EGB |
| Amperage | 45A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | EG |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Series G Enclosures, Switchboards, MCCs, Pow-R-Line Panelboards |
| Wire Gauge | 14-1/0 AWG |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Handle Mechanism |
|---|---|
| Accessories | Line and Load Terminals |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, IEC, UL |
| Temp Rating | 40C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed |
This unit mount EG-frame breaker is designed for installation in Eaton Series G enclosures, switchboards, motor control centers (MCCs), and Pow-R-Line panelboards.
In Eaton Series G nomenclature, the FF indicates that the breaker is equipped with fixed thermal and fixed magnetic trip units. The G signifies that the complete breaker includes both line and load lugs.
The EGB3045FFG is the predecessor to the Eaton Power Defense PDG13C0045TFFJ, which serves as its direct replacement for new installations.
The factory-installed line and load lugs on this breaker accommodate wire gauges ranging from 14 AWG up to 1/0 AWG.
While frequently applied on 240VAC and 480VAC systems, the EGB3045FFG is rated for a maximum of 600Y/347VAC for alternating current applications and 250VDC for direct current systems.
Yes, this thermal magnetic molded case circuit breaker supports reverse feed applications, allowing power to be connected to either the line or load terminals.
No, this breaker features a thermal magnetic trip unit with fixed thermal (Long Time) and fixed magnetic (Instantaneous) settings that cannot be field adjusted.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.