| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-B5/3-NA |
| Series | FAZ-NA |
| Amperage | 5A |
| Poles | 3 |
| Mounting Style | DIN Rail |
| Voltage | 480Y/277VAC, 96VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 480Y/277VAC, 10kA @ 96VDC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | DIN Rail Systems, Industrial Control Panels |
| Wire Gauge | 18-6 AWG (1 wire), 18-10 AWG (2 wires) |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | B |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Busbar System, Lockout Attachment, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, IEC 60947-2, RoHS, UL 489 |
| Approval | ABS, CE, CSA, cULus, DNV, IEC, Lloyd's, RoHS, UL, VDE |
| Temp Rating | -25C to 75C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Trip-Free Mechanism, Visual Trip Indicator, RoHS Compliant |
The B-curve magnetic trip point is 3 to 5 times the rated current. It is designed for applications with low inrush currents, such as resistive loads, heaters, and long wire runs, preventing nuisance tripping while providing fast short-circuit protection.
Yes, this breaker is UL 489 listed for branch circuit protection. It can also be used in applications that only require UL 1077 supplementary protection, but UL 1077 devices cannot be used in place of this UL 489 breaker.
Yes, it features a current-limiting design that interrupts fault currents within one-half cycle. This reduces peak let-through energy, offering superior protection for downstream components and the circuit itself.
No, it features a trip-free design. The breaker will trip and interrupt the circuit during an overload or short circuit even if the handle is physically held in the ON position.
Yes, this breaker supports field-installable accessories, including auxiliary switches and shunt trips, which can be mounted on the side of the breaker.
Yes, because its amperage rating is 20A or less, this 5A breaker is SWD (Switching Duty) rated and suitable for switching fluorescent lighting loads.
Yes, it includes a visual red and green contact position indicator on the front of the breaker to easily verify if the contacts are open or closed.
The breaker features captive terminal screws that cannot be lost during installation, ensuring a secure connection for the box lugs.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.