Eaton / Cutler-HammerFAZ-D10/3-NA
Quantity
New
Quantity
Eaton / Cutler-HammerFAZ-D10/3-NA
Eaton / Cutler-HammerFAZ-D13/3-NA
Eaton / Cutler-HammerFAZ-C15/3-NA
Eaton / Cutler-HammerFAZ-D30/3-NA
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-B7/3-NA |
| Series | FAZ-NA |
| Amperage | 7A |
| Poles | 3 |
| Mounting Style | DIN Rail |
| Voltage | 480Y/277VAC, 96VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 480Y/277VAC, 10kA @ 96VDC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | DIN Rail Systems, Industrial Control Panels |
| Wire Gauge | 18-6 AWG (1 wire), 18-10 AWG (2 wires) |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | B |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Alarm Switch, Lockout Attachment, Busbar System |
|---|---|
| Standards | CSA C22.2 No. 5, IEC 60947-2, RoHS, UL 489 |
| Approval | ABS, CE, CSA, cULus, DNV, IEC, Lloyd's, RoHS, UL, VDE |
| Temp Rating | -25C to 75C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Trip-Free Mechanism, Visual Trip Indicator |
The B curve characteristic means the breaker is designed to trip between 3 and 5 times the rated current. This makes it ideal for applications with low inrush currents, such as sensitive control circuitry and resistive loads.
Yes, the -NA suffix indicates this breaker is UL 489 listed for branch circuit protection. This allows it to be used as a primary branch circuit device, unlike UL 1077 supplementary protectors.
The FAZ-B7/3-NA is designed to snap directly onto a standard 35mm DIN rail.
Yes, this breaker is reverse feed capable. Power can be supplied to either the line or load side terminals without affecting the trip characteristics.
The breaker features a color-coded indicator on the front face that provides immediate visual confirmation of the contact status. It displays green when the breaker is OFF and red when it is ON.
Yes, the box lug terminals are rated to accept two wires ranging from 18 to 10 AWG. When terminating a single wire, the terminals accept 18 to 6 AWG.
Yes, it features a current limiting design that provides fast short circuit interruption. This reduces the peak let-through current and energy, offering superior protection for downstream components.
Yes, it is dual rated for both AC and DC applications. It carries a DC interrupting rating of 10kA at up to 96VDC.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.