Eaton / Cutler-HammerFAZ-D30/3-NA
Quantity
New
Quantity
Eaton / Cutler-HammerFAZ-D30/3-NA
Eaton / Cutler-HammerFAZ-C15/3-NA
Eaton / Cutler-HammerFAZ-D13/3-NA
Eaton / Cutler-HammerFAZ-D10/3-NA
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-D32/3-NA |
| Series | FAZ-NA |
| Amperage | 32A |
| Poles | 3 |
| Mounting Style | DIN Rail |
| Voltage | 480Y/277VAC, 96VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 480Y/277VAC, 10kA @ 96VDC |
| Frame Type | FAZ |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | DIN Rail Systems, Industrial Control Panels |
| Wire Gauge | 18-6 AWG |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | D |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Lockout Attachment, Busbar System |
|---|---|
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | ABS, CE, CSA, DNV, HACR, IEC, Lloyd's, RoHS, UL, VDE |
| Temp Rating | -25C to 75C |
| Construction Features | HACR Rated, Current Limiting, Reverse Feed, Trip-Free Mechanism |
The D-curve magnetic trip point is set between 10 and 20 times the rated current. This makes it ideal for highly inductive loads with significant inrush currents, such as motors, transformers, and power supplies, preventing nuisance tripping during startup.
Yes. The FAZ-NA series is UL 489 listed, meaning it is fully rated for branch circuit protection. It can also be used in applications where UL 1077 supplementary protectors are permitted.
No, the FAZ-D32/3-NA features a fixed thermal-magnetic trip unit. It provides long-time (L) and instantaneous (I) protection functions that cannot be field-adjusted.
This miniature circuit breaker mounts directly onto a standard 35mm DIN rail. It features box lug screw terminals that accept wire sizes from 18 AWG to 6 AWG.
Yes, power to this circuit breaker can be fed from either the line or load side, making it suitable for reverse-feed applications in industrial control panels.
Yes, it features a current-limiting design that interrupts fault currents within one-half cycle. This reduces peak let-through energy, providing superior protection for downstream components against short circuits.
As a UL 489 listed, D-curve breaker, it is designed for industrial control panels, motor control circuits, and equipment requiring branch circuit protection with high inrush currents, including HVAC and refrigeration (HACR) equipment.
FAZ-D32-3-NA is an alternate formatting of the exact same Eaton part number used by certain distributors. Both catalog numbers refer to the identical 32A, 3-pole, D-curve miniature circuit breaker.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.