Eaton / Cutler-HammerFAZ-D10/3-NA
Quantity
New
Quantity
Eaton / Cutler-HammerFAZ-D10/3-NA
Eaton / Cutler-HammerFAZ-D13/3-NA
Eaton / Cutler-HammerFAZ-C15/3-NA
Eaton / Cutler-HammerFAZ-D30/3-NA
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-D7/3-NA |
| Series | FAZ-NA |
| Amperage | 7A |
| Poles | 3 |
| Mounting Style | DIN Rail |
| Voltage | 480Y/277VAC, 96VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 480Y/277VAC, 10kA @ 96VDC |
| Frame Type | FAZ |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | DIN Rail Systems, Control Panels |
| Wire Gauge | 18-6 AWG |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | D |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Busbar System, Lockout Attachment, Shunt Trip, Undervoltage Release |
|---|---|
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489, RoHS |
| Approval | ABS, CCC, CE, CSA, DNV, HACR, IEC, Lloyd's, RoHS, SWD, UL, VDE |
| Temp Rating | -25C to 75C |
The D curve magnetic trip point is 10 to 20 times the rated current. This makes it ideal for applications with very high inrush currents, such as motors, transformers, and highly inductive loads, preventing nuisance tripping.
Yes, it is UL 489 listed, which means it is approved for feeder and branch circuit protection. It can also be used in applications where UL 1077 supplementary protectors are allowed.
Yes, this miniature circuit breaker is suitable for reverse feed applications.
Yes, it features a trip-free design, meaning the breaker will still trip during an overcurrent or short circuit event even if the handle is physically held in the ON position.
The FAZ-D7/3-NA is a direct replacement for the legacy Cutler-Hammer WMZT3D07 miniature circuit breaker.
Yes, because it is rated under 20 amps, it carries an SWD (Switching Duty) rating, making it suitable for switching fluorescent lighting loads.
The current-limiting design interrupts fault currents within one half cycle. This fast short-circuit interruption significantly reduces the peak let-through energy that could otherwise damage downstream equipment.
This breaker installs on a standard 35mm DIN rail using a built-in spring clip for secure mounting in control panels.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.