Eaton / Cutler-HammerFAZ-D10/3-NA
Quantity
New
Quantity
Eaton / Cutler-HammerFAZ-D10/3-NA
Eaton / Cutler-HammerFAZ-D13/3-NA
Eaton / Cutler-HammerFAZ-C15/3-NA
Eaton / Cutler-HammerFAZ-D30/3-NA
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-D8/3-NA |
| Series | FAZ-NA |
| Amperage | 8A |
| Poles | 3 |
| Mounting Style | DIN Rail |
| Voltage | 480Y/277VAC, 96VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 480Y/277VAC, 10kA @ 96VDC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | DIN Rail Systems, Control Panels |
| Wire Gauge | 18-6 AWG |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | D |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Busbar System, Lockout Attachment, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | None included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | ABS, CE, CSA, cULus, DNV, IEC, Lloyd's, UL, VDE |
| Temp Rating | -25C to 75C |
The D curve features a magnetic trip point of 10 to 20 times the rated current. This prevents nuisance tripping in highly inductive applications with significant startup inrush currents, such as motors, transformers, and power supplies.
The NA suffix indicates that the breaker is UL 489 listed for branch circuit protection in North America. It can also be used in applications where UL 1077 supplementary protectors are permitted.
Yes, FAZ-NA devices are current limiting. They are designed to interrupt fault currents within one half cycle, reducing peak let-through energy to protect downstream equipment.
Yes, Eaton FAZ-NA miniature circuit breakers are suitable for reverse feed applications. Power can be supplied to either the line or load side terminals.
The required tightening torque depends on the wire size. Use 21 lb-in for 18 to 12 AWG, 25 lb-in for 10 to 8 AWG, and 36 lb-in for 6 AWG conductors.
No, Eaton does not recommend the use of wire ferrules or crimping terminals for the FAZ-NA series box lugs. Bare wire connections are specified.
The breaker requires approximately 53 millimeters of space on a standard 35 millimeter DIN rail, as each pole has a module width of 17.7 millimeters.
Yes, it utilizes a trip-free design. The breaker will trip internally during an overcurrent or short circuit event even if the handle is physically held in the ON position.
The front of the breaker includes a color-coded indicator that provides immediate visual confirmation of the device status. It displays red when the contacts are closed and green when the contacts are open.
Yes, UL 489 listed branch circuit breakers can be used in place of UL 1077 supplementary protectors. However, UL 1077 devices cannot be used to replace UL 489 breakers.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.