Built for commercial and industrial applications, the Eaton FDB3100S is a 3-pole, 100A molded case circuit breaker from the proven Series C F-frame lineup. This unit-mount breaker installs into Eaton Series C panelboards, switchboards, and motor control centers. It serves as a direct replacement for older Cutler-Hammer FDB models. Rated at 14 kAIC at 480VAC, it features fixed thermal-magnetic trip units and factory-installed stainless steel terminals for superior corrosion resistance.
What is the difference between the Eaton FDB3100 and the FDB3100S?
The FDB3100S features factory-installed stainless steel line and load terminals. The standard FDB3100 typically ships with standard steel or aluminum lugs. Both share the same 100A, 3-pole F-frame footprint and electrical ratings.
Can I install the FDB3100S in an older Cutler-Hammer panel?
Yes, Eaton Series C F-frame breakers are fully backwards compatible with legacy Cutler-Hammer Series C panelboards, switchboards, and motor control centers.
What are the terminal torque specifications for the FDB3100S?
For the factory-installed slotted terminals, torque to 35 lb-in for 14-10 AWG, 40 lb-in for 8 AWG, 45 lb-in for 6-4 AWG, and 50 lb-in for 3-1/0 AWG conductors.
Can the FDB3100S be reverse fed?
Yes, all Eaton Series C F-frame thermal-magnetic circuit breakers, including the FDB3100S, are suitable for reverse feed applications.
Can I replace the factory lugs on the FDB3100S with different terminals?
Yes, the F-frame design allows for interchangeable line and load terminals. You can swap the factory stainless steel lugs for standard aluminum (e.g., 3TA100FD) or steel (e.g., 3T100FB) lugs if required by your application.
What does the "LI" trip function mean on this breaker?
"LI" stands for Long-Time and Instantaneous trip functions. The thermal-magnetic trip unit provides fixed thermal protection (Long-Time) for overloads and fixed magnetic protection (Instantaneous) for short circuits.
Does the FDB3100S accept internal accessories like shunt trips or auxiliary switches?
Yes, Eaton Series C F-frame breakers support a wide range of field-installable internal accessories, including shunt trips, auxiliary switches, and undervoltage releases. These are typically installed in the right or left pole accessory pockets.
Is the FDB3100S rated for high-intensity discharge (HID) lighting circuits?
No. While some Eaton F-frame breakers carry an HID rating, it only applies to models rated from 10A to 50A. At 100A, the FDB3100S is not suitable for HID applications.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 2 reviews.