| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | QBGFT1020 |
| Series | QBGFT |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Bolt-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards |
| Wire Gauge | 14-10 AWG (Cu), 12-10 AWG (Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Self-Test |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | QBGFT1020 |
| Series | QBGFT |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Bolt-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards |
| Wire Gauge | 14-10 AWG (Cu), 12-10 AWG (Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Self-Test |
Eaton / Cutler-HammerQBGFT1025
Eaton / Cutler-HammerQBGFT1015
Eaton / Cutler-HammerQBGFT1030
Eaton / Cutler-HammerQBGFT1040
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | QBGFT1020 |
| Series | QBGFT |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Bolt-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards |
| Wire Gauge | 14-10 AWG (Cu), 12-10 AWG (Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Self-Test |
This breaker is a Class A GFCI [1.1.1] with a 5 mA trip threshold, designed specifically for personnel protection.
It installs directly into Eaton Pow-R-Line panelboards, including the PRL1a, PRL2a, and PRL3X series, that are configured for Quicklag bolt-on branch circuit breakers.
Yes, it is the direct replacement for the legacy QBGF1020 and QB1020GF models. The updated QBGFT series features the self-test capabilities required to meet modern UL 943 standards.
The QBGFT1020 is equipped with a pigtail neutral wire. This pigtail must be securely landed on the panelboard neutral bus for the ground fault circuit interrupter and self-test functions to operate properly.
Yes, like all Eaton Quicklag miniature circuit breakers in this amp range, it is HACR rated and approved for use with heating, air conditioning, and refrigeration equipment.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.