The Q23020NC is part of Siemens' QT series, offering a space-saving quadplex design. By combining two 30A outer and two 20A inner poles, it maximizes capacity in crowded residential panels. This non-CTL plug-on breaker mounts into two standard spaces. Lacking a rejection clip, it is intended for pre-1968 Siemens and ITE load centers without notched bus stabs. Rated 10 kAIC at 120/240V, the thermal-magnetic unit features a non-common trip configuration for independent 120V branch circuits.

Specifications

Key specifications
Brand Siemens
Series QT
Amperage 30/20A
Poles 2
Mounting Style Plug-On
Voltage 120/240VAC
Phase 1
AIC Rating 10kA @ 120/240VAC
Fit and installation
Frame Type Q
Terminal Type Lugs
For Use With Siemens Load Centers (Non-CTL / Pre-1968)
Wire Gauge 14-6 AWG (Cu/Al)
Max Wire 6 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed
Standards and features
Special Classification Quadplex
Available Options Padlock Attachment
Standards CSA C22.2 No. 5, UL 489
Approval CSA, UL
Temp Rating 40C
Construction Features HACR Rated, Non-CTL, Non-Common Trip, Space Saver

Product FAQs

8 answers
What does the "NC" suffix indicate on the Q23020NC?

The "NC" stands for Non-CTL (Circuit Total Limiting). This means the breaker lacks a rejection clip and is designed specifically for older, pre-1968 Siemens and ITE load centers that do not have notched bus stabs.

How many panel spaces does this quadplex breaker require?

The Q23020NC mounts into two standard 1-inch panel spaces, allowing you to fit four independent poles into the space of two standard breakers.

What is the trip configuration of the Q23020NC?

This breaker features a non-common trip configuration. The poles operate independently, making it suitable for individual 120V branch circuits rather than 240V loads that require a common trip mechanism.

Can I install the Q23020NC in a modern Siemens load center?

Generally, no. Because it is a Non-CTL breaker without a rejection clip, it is intended for pre-1968 panels. Modern Siemens panels typically require CTL-rated breakers with rejection features to comply with circuit limits.

What is the difference between the Q23020NC and the Q23020CT2NC?

The Q23020NC has a non-common trip configuration for independent 120V circuits. The Q23020CT2NC features a common trip mechanism, which ties the handles together for use with 240V circuits. Both models are Non-CTL breakers.

How are the 30A and 20A poles arranged on this breaker?

The quadplex design is configured with two 30A outer poles and two 20A inner poles.

Is the Q23020NC compatible with legacy ITE panels?

Yes, this Non-CTL breaker is compatible with older ITE load centers that do not feature notched bus stabs, as well as equivalent legacy Siemens panels.

Does the Q23020NC include a rejection clip?

No, this breaker does not have a rejection clip. It is a Non-CTL design, meaning it will physically fit into any space in a compatible older panel, unlike CTL breakers which are restricted to specific notched stabs to prevent panel overloading.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.