Engineered for industrial distribution, the Square D BGA260201 is a 2-pole, 20A PowerPacT B-frame molded case circuit breaker. It delivers reliable thermal-magnetic protection. This unit installs into Square D I-Line panelboards and switchboards using an AB phase connection. It serves as a drop-in replacement for the legacy FA26020AB breaker. Rated 35 kAIC at 480VAC, it features fixed long-time and instantaneous (LI) trip functions and Visi-Trip visual indicators.
CSA C22.2 No 5, EN/IEC 60947-2, EN/IEC 60947-5-1, GB 14048.2, HACR, NEMA AB 1, NMX J-266, RoHS, UL 489
Approval
CCC, CE, CSA, EAC, IEC, NOM, UL
Temp Rating
-25C to 70C
Construction Features
HACR Rated, Visual Trip Indicator
Product FAQs
8 answers
What panelboards are compatible with the BGA260201 circuit breaker?
The BGA260201 is designed exclusively for use in Square D I-Line panelboards and switchboards. It will not fit in standard load centers or NQ/NF panelboards.
Does the PowerPacT BGA260201 replace older Square D breakers?
Yes, the PowerPacT B-frame series is the direct replacement for legacy Square D F-frame (FA and FH) I-Line circuit breakers.
How does the BGA260201 connect to the panelboard?
It features an I-Line style plug-in connection on the line side, which snaps directly onto the panelboard bus stack. The load side uses mechanical lugs for wire termination.
What does the "G" in the BGA260201 catalog number signify?
The "G" indicates the breaker interrupting rating tier. For the PowerPacT B-frame, the G-tier provides a 65kA interrupting rating at 240VAC and 35kA at 480VAC.
Are the trip settings on the BGA260201 adjustable?
No, this breaker features a thermal-magnetic trip unit with fixed long-time (thermal) and fixed instantaneous (magnetic) trip settings.
Can the BGA260201 I-Line breaker be reverse fed?
No. Because it utilizes a specialized I-Line plug-on connection for the line side, it must be fed from the panelboard bus and cannot be reverse fed.
What type of protection does the "LI" trip function provide?
The LI designation stands for Long-Time and Instantaneous trip functions. The long-time function protects against sustained overloads, while the instantaneous function protects against sudden short circuits.
What does the "A" in the BGA260201 catalog number mean?
In the PowerPacT catalog number system, the third letter "A" indicates that the breaker has an I-Line plug-on connection for the line side and mechanical lugs on the load side.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 4.9 out of 5 based on 7 reviews.