Part of the PowerPacT B-frame family, the BGA24025Y1 is a 2-pole, 25A molded case circuit breaker. Built for commercial power distribution, it provides thermal-magnetic long-time and instantaneous (LI) protection with an AB phase connection. It installs into Square D I-Line panelboards and switchboards, serving as a replacement for legacy FA24025AB breakers. Rated for 65 kAIC at 240 VAC, this HACR-rated unit includes a Visi-Trip indicator for clear visual confirmation of a tripped status.
What panelboards are compatible with the BGA24025Y1 circuit breaker?
This PowerPacT B-frame breaker features an I-Line plug-in mounting style, making it compatible with Square D I-Line panelboards and switchboards. It connects directly to the panel bus for fast installation.
Can the BGA24025Y1 replace older Square D F-frame breakers?
Yes, PowerPacT B-frame I-Line breakers are the designated modern replacement for legacy Square D FA and FH series breakers. They maintain the same 1.5-inch per pole width, allowing them to drop into existing I-Line panelboards without requiring bus modifications or blank fillers.
Which specific legacy circuit breaker does the BGA24025Y1 replace?
The BGA24025Y1 serves as a direct drop-in replacement for the discontinued Square D FA24025AB circuit breaker. It provides the same 25-amp rating, 2-pole configuration, and AB phase connection for I-Line panels.
What wire sizes and materials are accepted by the lugs on this breaker?
The factory-installed lugs on the BGA24025Y1 are dual-rated for both aluminum and copper conductors. They accept wire sizes ranging from 14 AWG to 2/0 AWG.
What type of trip unit is installed in the BGA24025Y1?
This breaker is equipped with a fixed thermal-magnetic trip unit. It provides Long-Time thermal protection for overloads and Instantaneous magnetic protection for short circuits, commonly referred to as an LI trip function.
What phase connection does the BGA24025Y1 use?
This specific I-Line circuit breaker is factory-configured with an AB phase connection for installation onto the panelboard bus.
Does the BGA24025Y1 include a visual trip indicator?
Yes, PowerPacT B-frame breakers feature a Visi-Trip indicator. This provides clear visual confirmation of a tripped status, allowing for rapid fault identification during maintenance.
Is the BGA24025Y1 suitable for HVAC applications?
Yes, this circuit breaker is HACR rated, meaning it is approved for use with heating, air conditioning, and refrigeration equipment.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.