The KGL32225 is a 3-pole, 225A molded case circuit breaker from Square D's legacy K-Frame series. It provides reliable protection for commercial and industrial systems. This unit-mount breaker installs into Square D switchboards and motor control centers. It is replaced by the modern PowerPacT J-Frame (JGL36225). Rated for 65kAIC at 240VAC, it utilizes fixed thermal and magnetic trip elements (LI). The breaker is HACR rated and accepts 6 AWG to 350 kcmil wire.
What is the modern replacement for the legacy KGL32225?
The Square D KGL32225 is a legacy K-frame breaker. It has been replaced by the modern PowerPact J-Frame series, specifically catalog number JGL36225.
Can the KGL32225 be installed in an I-Line panelboard?
No. The KGL32225 is a unit mount, feed-thru circuit breaker. It is designed to be bolted directly to a backpan in switchboards, motor control centers, or enclosures. I-Line panelboards require a breaker with plug-on line-side jaws.
What does the "G" in the KGL32225 catalog number signify?
In Square D legacy K-frame nomenclature, the "G" designates the interrupting capacity tier. For this specific breaker, it indicates a 65kAIC rating at 240VAC.
What are the wire size and material requirements for the KGL32225 lugs?
The standard lugs accept wire gauges from 6 AWG up to 350 kcmil. They are dual-rated for terminating both aluminum and copper (Al/Cu) conductors.
Are the trip settings on the KGL32225 adjustable?
No. This thermal-magnetic breaker features fixed long-time and fixed instantaneous (LI) trip elements. Neither the thermal overload nor the magnetic short-circuit thresholds can be adjusted in the field.
How are the line and load connections made on the KGL32225?
Because it is a feed-thru, unit mount breaker, both the line and load sides utilize mechanical lugs for hardwiring. It does not plug onto a busbar.
What equipment is the KGL32225 designed to protect?
This 3-pole, 225A breaker is commonly used for main or feeder circuit protection in Square D switchboards, motor control centers, and standalone enclosures operating at 240VAC.
What safety verifications are required before installing the KGL32225?
Always de-energize the equipment before installation. Verify that the available fault current at the installation point does not exceed the breaker's 65kAIC maximum interrupting rating at 240VAC.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.