Designed for maximum distribution efficiency, the Square D LJP36250CU31X is a 250A, 3-pole molded case circuit breaker from the PowerPacT L-Frame series. It provides reliable service for motor control centers and industrial panels. This breaker features a unit-mount design with lug terminals, accepting aluminum or copper wiring. A standout feature is its 100% continuous current rating, paired with a MicroLogic 3.3 trip unit for adjustable long-time and instantaneous (LI) protection.

Specifications

Key specifications
Brand Square D
Part Number LJP36250CU31X
Series LJP
Amperage 250A
Poles 3
Mounting Style Unit Mount
Voltage 240VAC, 480VAC, 600VAC
Phase 3
AIC Rating 100kA @ 240VAC, 65kA @ 480VAC, 25kA @ 600VAC
Electrical ratings
Amperage Range 70-250A
Fit and installation
Frame Type LJP
Terminal Type Lugs
For Use With Square D QED Switchboards, Industrial Control Panels, Motor Control Centers
Wire Gauge (1) 2 AWG-500 kcmil (Al) or (1) 2 AWG-600 kcmil (Cu)
Max Wire 600 kcmil
Min Wire 2 AWG
Protection and operation
Trip Technology Electronic Trip
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Adjustable
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle, Lug Kits
Accessories MicroLogic 3.3 Trip Unit
Standards CSA C22.2 No 5, IEC 60947-2, NEMA AB 1, UL 489
Approval CCC, CE, CSA, IEC, NEMA, NOM, UL, UKCA
Temp Rating -25C to 70C
Construction Features HACR Rated, Current Limiting, True RMS Sensing, Visual Trip Indicator, Double-Break Rotary Contact Structure, Trip-Free Mechanism, 100% Rated, RoHS Compliant, Mercury Free

Product FAQs

7 answers
Is the LJP36250CU31X circuit breaker 100% rated?

Yes, the "C" in the catalog number indicates this breaker is rated for 100% continuous duty. This allows the breaker to carry its full 250A capacity continuously without the standard 80% derating requirement, provided it is installed in a properly sized and ventilated enclosure.

What specific trip unit is installed in the LJP36250CU31X?

The "U31X" suffix indicates it is equipped with a Micrologic 3.3 electronic trip unit. This solid-state unit provides highly accurate, adjustable Long-Time and Instantaneous (LI) protection for precise coordination in commercial and industrial systems.

Can the LJP36250CU31X be installed in a Square D I-Line panelboard?

No. The "P" in the LJP prefix means this is a unit-mount (feed-thru) breaker with lugs on both ends. It is designed to be bolted to a backpan in QED switchboards, motor control centers, or industrial control panels. For an I-Line panelboard, you need the LJA36250CU31X plug-on variant.

What are the acceptable wire sizes for the standard lugs on this breaker?

The factory-installed lugs accept a single conductor per phase, ranging from 2 AWG to 600 kcmil for copper (Cu) wire, or 2 AWG to 500 kcmil for aluminum (Al) wire.

What is the difference between the LJP36250CU31X and the LJA36250CU31X?

Both are 250A, 100% rated, J-interrupting L-Frame breakers with Micrologic 3.3 trip units. The difference is the mounting style. The LJP is a unit-mount breaker with lugs on both the line and load sides, while the LJA features an I-Line plug-on connection for the line side.

What does the "J" in the LJP36250CU31X catalog number signify?

The "J" designates the interrupting rating tier for this PowerPacT L-Frame breaker. It indicates a high interrupting capacity of 65kAIC at 480VAC and up to 100kAIC at 240VAC, making it suitable for systems with substantial available fault currents.

Does the LJP36250CU31X provide ground fault protection?

No, the Micrologic 3.3 trip unit only provides Long-Time and Instantaneous (LI) protection. If your application requires equipment ground fault protection, you will need a breaker equipped with a Micrologic 6.3 (LSIG) trip unit.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.