Engineered for industrial applications, the ABB XT1SU3015AFD000XXX is a 3-pole molded case circuit breaker from the SACE Tmax XT family. It provides dependable long-time and instantaneous (LI) protection. This unit mount MCCB integrates into ABB ReliaGear neXT panelboards and SB switchboards. It replaces legacy T1N015TL breakers and includes load side lugs for streamlined wiring. Rated 35kAIC at 480V, the 15A breaker features fixed thermal-magnetic trip settings and double insulation.
Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Padlock Attachment
Accessories
Load Side Lugs
Standards
CSA C22.2 No. 5, IEC 60947-2, UL 489
Approval
CE, CSA, cULus, IEC, UL
Temp Rating
-25C to 70C
Construction Features
HACR Rated, Reverse Feed, Double Insulated
Product FAQs
7 answers
What does the "S" in the XT1S designation indicate for this breaker?
The "S" denotes the Standard interrupting capacity tier for the ABB Tmax XT1 frame. For this 15A breaker, it provides a maximum interrupting rating of 35kA at 480VAC and 65kA at 240VAC.
Can the thermal or magnetic trip settings be adjusted in the field?
No, this breaker features a Fixed Thermal and Fixed Magnetic (TMF) trip unit. Both the long-time overload and instantaneous short circuit protection thresholds are factory set and cannot be modified by the installer.
Which panelboards and switchboards are approved for use with this XT1 breaker?
This unit mount breaker integrates directly into ABB ReliaGear neXT panelboards, ReliaGear SB switchboards, and SACE Tmax XT panelboards. It is commonly used when upgrading or expanding these specific distribution systems.
Can this breaker be used to replace legacy GE circuit breakers?
Yes, the ABB Tmax XT series serves as the replacement for several legacy GE lines following ABB acquiring GE Industrial Solutions. Specifically, this XT1SU3015AFD000XXX model can replace legacy T1N015TL breakers.
What temperature rating should be used when sizing conductors for the factory lugs?
Conductors should be sized based on the 75 degrees C ampacity column in the National Electrical Code (NEC). While 90 degrees C insulated wire can be installed, its ampacity must be based on the 75 degrees C rating of the breaker lugs.
What type of protection does the LI trip function provide?
The LI designation indicates that the thermal-magnetic trip unit provides Long-Time (L) protection against sustained overloads and Instantaneous (I) protection against short circuits.
What is the maximum amperage capacity of the XT1 frame?
While this specific breaker is rated for 15A, the ABB Tmax XT1 frame size can support up to 125A maximum continuous current.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.