| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3040H |
| Series | BAB |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3040H-R |
| Series | BAB |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Eaton / Cutler-HammerBAB3040HS
Eaton / Cutler-HammerBAB3045HS
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3040H |
| Series | BAB |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
This breaker is designed specifically for Eaton, Cutler-Hammer, and legacy Westinghouse Pow-R-Line 1a (PRL1a) panelboards.
Yes. Eaton acquired the Cutler-Hammer and Westinghouse electrical distribution lines. The BAB3040H is the direct drop-in replacement for older Westinghouse and Cutler-Hammer breakers carrying the BAB3040 or BAB3040H catalog numbers.
Yes. If your electrical system requires a short-circuit interrupting capacity higher than 10 kAIC, you can upgrade to the Eaton QBHW3040. It shares the same physical footprint and bus connection but provides a 22 kAIC rating at 240VAC.
Yes, all Eaton Quicklag BAB breakers from 15 to 100 amps are HACR rated. This makes the breaker code-compliant for protecting heating, air conditioning, and refrigeration equipment circuits.
In the Eaton Quicklag series, the H suffix designates 240V rated two-pole and three-pole models. This distinguishes them from the standard 120/240V rated versions in the BAB product line.
The breaker features metal mounting brackets that physically bolt directly to the panelboard bus bar. This ensures a highly secure, vibration-resistant electrical connection required for commercial and industrial panelboards.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.