Eaton / Cutler-HammerBAB3060HS
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3060H |
| Series | BAB |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards |
| Wire Gauge | 8-1/0 AWG (Al/Cu) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3060H-R |
| Series | BAB |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards |
| Wire Gauge | 8-1/0 AWG (Al/Cu) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated |
Eaton / Cutler-HammerBAB3060HS
Eaton / Cutler-HammerBAB3070HS
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3060H |
| Series | BAB |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards |
| Wire Gauge | 8-1/0 AWG (Al/Cu) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated |
This bolt-on miniature circuit breaker is designed for use in Eaton Pow-R-Line panelboards, as well as legacy Westinghouse and Cutler-Hammer panelboards that accept Quicklag BAB-frame breakers.
No. The BAB3060H is a bolt-on breaker with an extended tang line terminal designed for industrial and commercial panelboards. It will not snap into standard plug-on residential load centers.
The line side connects directly to the panelboard bus via an extended tang bolt-on connection. The load side features a box lug terminal that accommodates 8 AWG to 1/0 AWG copper or aluminum wiring.
The load terminals are rated for both copper and aluminum (Al/Cu) conductors. When installing aluminum wiring, it is standard practice to apply an approved oxide-inhibiting joint compound to ensure a secure, safe connection.
Yes. Eaton acquired the Cutler-Hammer and Westinghouse electrical distribution lines. The current Eaton BAB3060H is a direct, UL 489 listed replacement for older breakers with the identical BAB3060H catalog number.
The BAB3060H has a maximum interrupting rating of 10,000 amps (10kAIC) at 240VAC. If your application's available fault current exceeds 10kA, you must use a higher-rated breaker, such as the Eaton QBHW series, or employ an approved series-rated system.
No. The BAB3060H utilizes a fixed thermal-magnetic trip unit. Both the long-time overload and instantaneous short-circuit functions are factory calibrated and cannot be adjusted in the field.
The BAB3060H is a 60-amp breaker and does not carry an SWD (Switching Duty) or HID rating. Under the National Electrical Code, SWD and HID ratings are restricted to 15-amp and 20-amp breakers. It is strictly intended for standard branch circuit and equipment protection.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.