Eaton / Cutler-HammerCHFN115GF
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | CH115GFI |
| Series | CH |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Type CH Load Centers |
| Wire Gauge | 14-6 AWG (Cu/Al) |
| Max Wire | 6 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | UL 489, UL 943, CSA C22.2 |
| Approval | UL, CSA |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, SWD Rated |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | CH115GFI-R |
| Series | CH |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Type CH Load Centers |
| Wire Gauge | 14-6 AWG (Cu/Al) |
| Max Wire | 6 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | UL 489, UL 943, CSA C22.2 |
| Approval | UL, CSA |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, SWD Rated |
Eaton / Cutler-HammerCHFN115GF
Eaton / Cutler-HammerCHFGFT115
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | CH115GFI |
| Series | CH |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Type CH Load Centers |
| Wire Gauge | 14-6 AWG (Cu/Al) |
| Max Wire | 6 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | UL 489, UL 943, CSA C22.2 |
| Approval | UL, CSA |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, SWD Rated |
The CH115GFI is designed exclusively for Eaton and Cutler-Hammer Type CH load centers. It requires a 3/4-inch space per pole and will not fit in 1-inch Type BR panels.
This breaker provides Class A ground fault protection, which trips when a ground fault of 5mA is detected. This meets requirements for personnel protection in locations like bathrooms, kitchens, and outdoor receptacles.
No, the CH115GFI features a pigtail neutral connection. The coiled white pigtail wire connects directly to the neutral bus bar in the panel, making it compatible with standard Type CH load centers that do not have a plug-on neutral design.
For the GFCI protection to function properly, the neutral wire from the branch circuit must be connected directly to the load neutral terminal on the breaker itself, not to the panel neutral bus bar.
Yes. Eaton acquired Cutler-Hammer and continues to manufacture the Type CH line. The Eaton CH115GFI is the direct replacement for the legacy Cutler-Hammer version with the exact same catalog number.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.