Eaton / Cutler-HammerCHFN230GF
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | CH230GFI |
| Series | CH |
| Amperage | 30A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton CH Load Centers |
| Wire Gauge | 14-4 AWG |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Shunt Trip |
| Accessories | Pigtail Neutral |
| Standards | CSA C22.2, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | Common Trip |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | CH230GFI-R |
| Series | CH |
| Amperage | 30A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton CH Load Centers |
| Wire Gauge | 14-4 AWG |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Shunt Trip |
| Accessories | Pigtail Neutral |
| Standards | CSA C22.2, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | Common Trip |
Eaton / Cutler-HammerCHFN230GF
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | CH230GFI |
| Series | CH |
| Amperage | 30A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton CH Load Centers |
| Wire Gauge | 14-4 AWG |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Shunt Trip |
| Accessories | Pigtail Neutral |
| Standards | CSA C22.2, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | Common Trip |
This Class A GFCI breaker is designed to trip when it detects a ground fault leakage current of 5mA, protecting personnel from electrical shock.
As a 2-pole Type CH circuit breaker, it requires two 3/4-inch spaces, taking up a total of 1.5 inches of physical width on the load center bus.
No. The CH230GFI features a proprietary plug-on clip design that is exclusively compatible with Eaton and classic Cutler-Hammer Type CH load centers. It will not fit BR-style or other manufacturer panels.
This model relies on a traditional pigtail neutral. The attached coiled white wire must be routed and secured directly to the neutral bus bar in the panel for the internal ground-fault protection circuitry to function correctly.
The CH230GFT is the newer self-testing version of this breaker, designed to meet updated UL standards by automatically running internal diagnostic tests. The older CH230GFI requires the user to manually press the test button to verify functionality, though both offer identical physical dimensions, fitment, and 5mA protection.
A 30-amp, 2-pole GFCI is commonly used to protect 240V circuits in damp or wet locations, such as swimming pool pumps, hot tubs, spa panels, and outdoor equipment, strictly following NEC safety requirements.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.