Eaton / Cutler-HammerBAB3035HS
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3035H-R |
| Series | BAB |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3035H-R |
| Series | BAB |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Eaton / Cutler-HammerBAB3035HS
Eaton / Cutler-HammerBAB3040HS
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3035H-R |
| Series | BAB |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
This bolt-on breaker installs in Eaton Pow-R-Line series commercial panelboards. It is also completely backward compatible with older Westinghouse, Cutler-Hammer, and Bryant panelboards that were designed to accept Quicklag bolt-on miniature breakers.
Yes. Eaton acquired the distribution equipment divisions of Westinghouse, Cutler-Hammer, and Bryant. The modern Eaton BAB3035H is the direct manufacturer equivalent and replacement for the legacy brands sharing this exact catalog number.
No. This is a bolt-on circuit breaker engineered specifically for commercial and industrial panelboards. It must be mechanically bolted to the panel bus and cannot be snapped into a standard residential plug-on load center.
According to Eaton Quicklag specifications, the box lug torque depends on the installed wire gauge. Standard torque values are 20 in-lbs for 14 to 10 AWG, 25 in-lbs for 8 AWG, and 27 in-lbs for 6 to 4 AWG conductors. Always verify against the printed label on the side of your breaker prior to termination.
This breaker utilizes a fixed, non-interchangeable thermal-magnetic trip unit. It incorporates a thermal bimetal element to provide long-time overload protection and a magnetic mechanism to handle instantaneous short-circuit protection.
The BAB3035H is rated to safely interrupt a maximum of 10,000 amps (10kAIC) during a fault on a 240V system. If your facility requires a higher short-circuit current rating, you must step up to the QBHW series (22kAIC) or the HBAX series (65kAIC) breakers, which share the same physical footprint.
Yes. Eaton Quicklag BAB miniature circuit breakers rated from 15 to 100 amps carry an HACR rating, making them strictly compliant and safe for protecting dedicated heating, air conditioning, and refrigeration equipment circuits.
No. While many 15A and 20A single-pole breakers in the Eaton BAB series carry a Switching Duty (SWD) rating for 120V fluorescent lighting loads, 35A three-pole breakers like the BAB3035H are not SWD rated.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.