Eaton / Cutler-HammerBQC2252115
Quantity
New
Quantity
Eaton / Cutler-HammerBQC2252115
Eaton / Cutler-HammerBQC2252120
Eaton / Cutler-HammerBQC2152130
Eaton / Cutler-HammerBQC215230
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | BQC |
| Amperage | 25/25A |
| Poles | 4 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | BR |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Eaton Type BR Load Centers |
| Wire Gauge | 14-4 AWG |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Special Classification | Quadplex |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Rejection Tab |
| Standards | Federal Specification W-C375, UL 489 |
| Approval | HACR, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, Rejection Tab, Common Trip |
This breaker is designed for Eaton Type BR load centers that feature notched bus stabs. Because it is a CTL (Circuit Total Limiting) breaker, it will not seat properly in non-CTL panels or unnotched bus positions.
Yes. Eaton acquired the Cutler-Hammer, Bryant, and Westinghouse load center lines. The modern Eaton Type BR series, including the BQC225225, is the UL-listed OEM replacement for legacy Bryant, Westinghouse, and Challenger panels that accept BR-type quad breakers.
The BQC series features internal common trip mechanisms for both the inner and outer circuits. If a fault occurs on one leg of the 25A outer circuit or the 25A inner circuit, both poles of that specific circuit will trip simultaneously, making it suitable for 240V loads.
Yes, the BQC225225 includes a built-in CTL rejection tab. This safety feature ensures the breaker can only be installed in panel positions specifically designed to accept tandem or quad breakers, preventing panel overloading.
Yes, this breaker is HACR rated, making it suitable for use with heating, air conditioning, and refrigeration equipment that requires a 25A 240V circuit.
BQ quad breakers have independent trip on the 2-pole circuits, meaning each pole trips independently. BQC breakers, like the BQC225225, feature common trip on the 2-pole circuits, which is required for dedicated 240V loads where both hot legs must disconnect simultaneously.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.