Skip to main content
Expedited shipping available at checkout

Eaton / Cutler-Hammer CHFN260GF GFCI Miniature Circuit Breaker

  • 60A
  • 2 Pole
  • Plug-On
Eaton / Cutler-Hammer CHFN260GF
GFCI Miniature Circuit Breaker
Brand Eaton / Cutler-Hammer
SKU CHFN260GF
Select Item Condition
Earn 198 SuperPoints
  • 60A
  • 2 Pole
  • Plug-On

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Eaton / Cutler-Hammer CHFN260GF - 60A GFCI Miniature Circuit Breaker

Eaton / Cutler-Hammer CHFN260GF - 60A GFCI Miniature Circuit Breaker

New

$198.80 In Stock

Quantity

Similar Items

Description

Supplying robust 60-amp capacity, this two-pole GFCI device delivers essential 5mA shock protection for large equipment. The integrated pigtail neutral and automated self-test diagnostics ensure continuous operational safety. Designed exclusively for Eaton CH series panelboards, the plug-on format occupies two 3/4-inch spaces. It acts as an exact substitute for legacy CHFGF260, CHN260GF, and CH260GF breakers. The thermal-magnetic trip mechanism includes a visual flag to simplify troubleshooting.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Series CHFN
Amperage 60A
Poles 2
Mounting Style Plug-On
Voltage 120/240VAC
Phase 1
AIC Rating 10kA @ 120/240VAC
Fit and installation
Terminal Type Box Lugs
For Use With Eaton CH Load Centers
Wire Gauge 14-3 AWG
Max Wire 3 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LIG
Trip Function Long-Time, Instantaneous, Ground Fault
Trip Adjustability Fixed
Standards and features
Special Classification GFCI
Available Options Padlock Attachment
Accessories Pigtail Neutral
Standards UL 489, UL 943, CSA C22.2 No. 5
Approval UL, CSA
Temp Rating 40C
Construction Features HACR Rated, Visual Trip Indicator, Self-Test, Common Trip

Product FAQs

8 answers
Can I install this breaker in an Eaton BR or Square D QO load center?

No. The CHFN260GF is specifically designed for Eaton Cutler-Hammer Type CH load centers. It utilizes a 3/4-inch plug-on mounting format that is not physically compatible with Type BR, QO, or Homeline panels.

How much physical space does this breaker require in a panel?

It requires two adjacent 3/4-inch spaces, occupying a total of 1.5 inches of bus bar space in an Eaton Type CH load center.

Is this breaker rated for personnel protection or equipment protection?

This is a Class A GFCI device rated for personnel protection. It is designed to trip when it detects a residual ground fault current of 5mA, safeguarding users from electric shock.

What common applications require a 60A GFCI circuit breaker?

A 60-amp ground fault breaker is most frequently installed for large outdoor water applications. This includes powering high-capacity hot tubs, swimming pool equipment panels, and large spa heaters where dedicated personnel protection is mandated by the NEC.

How should the neutral wires be terminated on this pigtail GFCI?

The factory-installed coiled white pigtail wire must connect directly to the main neutral bus bar in the panel. The neutral wire returning from your load must terminate directly onto the neutral lug located on the breaker itself.

Can this model be used to replace legacy CH260GF or CHN260GF breakers?

Yes. The CHFN260GF is Eaton's direct, modernized replacement for older 60-amp Type CH GFCI models, acting as a complete substitute for legacy catalog numbers including CH260GF, CHN260GF, and CHFGF260.

What advantages does the CHFN series offer over older legacy models?

The upgraded CHFN platform features advanced electronics that perform continuous self-testing to ensure the ground fault circuitry remains operational. It also includes visual trip indicators to simplify system troubleshooting.

How does the breaker indicate the cause of a circuit trip?

The CHFN platform features advanced internal diagnostics and a visual trip indicator system. This allows an electrician or panel builder to easily differentiate between a standard thermal overload, a severe short circuit, or a ground fault event.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.

Reviews

5.0
Rated 5.0 out of 5 stars
Based on 1 review
Total 5 star reviews: 1 Total 4 star reviews: 0 Total 3 star reviews: 0 Total 2 star reviews: 0 Total 1 star reviews: 0
Rating
Ratings
1 review
  • CP
    Cordell P.
    Verified Buyer
    I recommend this product
    Rated 5 out of 5 stars
    5/16/26
    Perfect