Eaton / Cutler-HammerCHFN250GF
Quantity
New
Quantity
Eaton / Cutler-HammerCHFN250GF
Eaton / Cutler-HammerCHFN240GF
Eaton / Cutler-HammerCHFN220GF
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | CHFN |
| Amperage | 60A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton CH Load Centers |
| Wire Gauge | 14-3 AWG |
| Max Wire | 3 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | UL 489, UL 943, CSA C22.2 No. 5 |
| Approval | UL, CSA |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Visual Trip Indicator, Self-Test, Common Trip |
No. The CHFN260GF is specifically designed for Eaton Cutler-Hammer Type CH load centers. It utilizes a 3/4-inch plug-on mounting format that is not physically compatible with Type BR, QO, or Homeline panels.
It requires two adjacent 3/4-inch spaces, occupying a total of 1.5 inches of bus bar space in an Eaton Type CH load center.
This is a Class A GFCI device rated for personnel protection. It is designed to trip when it detects a residual ground fault current of 5mA, safeguarding users from electric shock.
A 60-amp ground fault breaker is most frequently installed for large outdoor water applications. This includes powering high-capacity hot tubs, swimming pool equipment panels, and large spa heaters where dedicated personnel protection is mandated by the NEC.
The factory-installed coiled white pigtail wire must connect directly to the main neutral bus bar in the panel. The neutral wire returning from your load must terminate directly onto the neutral lug located on the breaker itself.
Yes. The CHFN260GF is Eaton's direct, modernized replacement for older 60-amp Type CH GFCI models, acting as a complete substitute for legacy catalog numbers including CH260GF, CHN260GF, and CHFGF260.
The upgraded CHFN platform features advanced electronics that perform continuous self-testing to ensure the ground fault circuitry remains operational. It also includes visual trip indicators to simplify system troubleshooting.
The CHFN platform features advanced internal diagnostics and a visual trip indicator system. This allows an electrician or panel builder to easily differentiate between a standard thermal overload, a severe short circuit, or a ground fault event.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.