Built to maximize available panel space, the Eaton BQ230240 is a 30/40A quadplex breaker. By combining two 30A and two 40A independent circuits into a single unit, it allows for system expansion without the need for a larger electrical box. This plug-on breaker installs into Eaton BR, Bryant, Challenger, and Westinghouse load centers. It occupies two standard 1-inch spaces and features a CTL rejection tab. It delivers reliable thermal-magnetic protection with a 10 kAIC rating at 120/240V.
CSA C22.2 No. 5, Federal Specification W-C375, UL 489
Approval
CSA, UL
Temp Rating
60C to 75C
Construction Features
HACR Rated, Rejection Tab
Product FAQs
7 answers
Can I install the Eaton BQ230240 in any Eaton BR load center?
No. The BQ230240 is a CTL (Circuit Total Limitation) breaker equipped with a rejection tab. It must be installed in an Eaton BR load center with notched bus stabs designed to accept tandem or quadplex breakers. It cannot be installed in non-notched panel slots.
How are the 30A and 40A circuits configured on the BQ230240 quadplex breaker?
This quadplex breaker provides a 30A two-pole circuit on the outer poles and a 40A two-pole circuit on the inner center poles.
How much panel space does the BQ230240 require?
This quadplex breaker provides four poles of protection but only requires two standard 1-inch spaces in a compatible load center.
Does the BQ230240 feature common trip or independent trip mechanisms?
The BQ series features independent trip mechanisms. The outer 30A circuit and the inner 40A circuit will trip independently of one another during a fault. If you require a common trip for all four poles, you need the BQC series equivalent.
Can the Eaton BQ230240 replace older Bryant or Westinghouse quadplex breakers?
Yes. Eaton BR series breakers are UL listed to replace legacy Bryant, Challenger, and Westinghouse Type BR breakers of the same configuration.
Is the Eaton BQ230240 rated for HVAC equipment?
Yes, all Eaton Type BQ quadplex circuit breakers carry a listing for HACR (Heating, Air Conditioning, and Refrigeration) applications, making them suitable for protecting HVAC motor loads.
Can I modify or remove the rejection tab on the BQ230240 to fit a non-CTL panel?
No. Removing or modifying the CTL rejection tab violates the UL listing and NEC requirements. If your panel does not have notched bus stabs, you must use a non-CTL breaker if permitted by the panel labeling, or upgrade the load center.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 4.9 out of 5 based on 73 reviews.
4.9
Rated 4.9 out of 5 stars
Based on 73 reviews
5
Rated out of 5 stars
69
4
Rated out of 5 stars
3
3
Rated out of 5 stars
0
2
Rated out of 5 stars
0
1
Rated out of 5 stars
1
Reviews Summary
Generated by AI from 67 most recent customer reviews
Last updated 6/3/26
Customers say these breakers arrive quickly and fit perfectly for their electrical needs. Fast shipping and competitive pricing are frequently mentioned, with many users appreciating the availability of hard-to-find and older-style breakers. The products are well-packaged and arrive in good condition. Most customers report successful installations and reliable performance. A few note missing items from orders or concerns about product condition, though the majority express satisfaction with their purchases and indicate they would order again.