Eaton / Cutler-HammerBQC2302130
Quantity
New
Quantity
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | BR |
| Amperage | 30/30/30/30A |
| Poles | 4 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | BR |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Type BR Load Centers |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Special Classification | Quadplex |
|---|---|
| Available Options | Padlock Attachment |
| Standards | UL 489, Federal Specification W-C375 |
| Approval | UL |
| Temp Rating | 60C, 75C |
| Construction Features | Non-CTL, Common Trip, HACR Rated |
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | BR |
| Amperage | 30/30/30/30A |
| Poles | 4 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | BR |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Type BR Load Centers |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Special Classification | Quadplex |
|---|---|
| Available Options | Padlock Attachment |
| Standards | UL 489, Federal Specification W-C375 |
| Approval | UL |
| Temp Rating | 60C, 75C |
| Construction Features | Non-CTL, Common Trip, HACR Rated |
Eaton / Cutler-HammerBQC2302130
Eaton / Cutler-HammerBQC230230
Eaton / Cutler-HammerBRDC230230
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | BR |
| Amperage | 30/30/30/30A |
| Poles | 4 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | BR |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Type BR Load Centers |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Special Classification | Quadplex |
|---|---|
| Available Options | Padlock Attachment |
| Standards | UL 489, Federal Specification W-C375 |
| Approval | UL |
| Temp Rating | 60C, 75C |
| Construction Features | Non-CTL, Common Trip, HACR Rated |
The BR430 is designed for use in Eaton and legacy Cutler-Hammer Type BR load centers. It is also UL approved for installation in compatible Westinghouse, Challenger, and Bryant panels that accept Type BR breakers.
The BR430 is a Non-CTL (Circuit Total Limiting) replacement breaker. It lacks a rejection tab, allowing it to be installed in older non-CTL load centers to maximize circuit capacity in existing panels.
This quadplex breaker consolidates four 30A poles into a compact footprint, requiring only two standard 1-inch spaces on the panel bus.
The BR430 features independent trip mechanisms for both the outer and center poles, effectively providing four independent 120V, 30A circuits. A fault on one pole will trip independently without forcing the other circuits in the quadplex assembly to trip.
While both are 30A quadplex breakers requiring two panel spaces, the BR430 features independent trip mechanisms for the center and outer poles. The BRDC230230 features a common trip mechanism, which is required by NEC code when supplying 240V loads that need simultaneous disconnects.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.