Eaton / Cutler-HammerFAZ-D5/2-NA
Quantity
New
Quantity
Eaton / Cutler-HammerFAZ-D5/2-NA
Eaton / Cutler-HammerFAZ-C1/2-NA
Eaton / Cutler-HammerFAZ-C6/1-NA-SP
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-B6/2-NA |
| Series | FAZ-NA |
| Amperage | 6A |
| Poles | 2 |
| Mounting Style | DIN Rail |
| Voltage | 480Y/277VAC, 96VDC |
| Phase | 1 |
| AIC Rating | 10kA @ 480Y/277VAC, 10kA @ 96VDC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | DIN Rail Panels, Industrial Control Panels |
| Wire Gauge | 18-6 AWG (1 wire), 18-10 AWG (2 wires) |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | B |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Lockout Attachment, Busbar System |
|---|---|
| Standards | CSA C22.2 No. 5, IEC 60947-2, RoHS, UL 489 |
| Approval | ABS, CE, CSA, cULus, DNV, IEC, Lloyd's, RoHS, UL, VDE |
| Temp Rating | -25C to 75C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Trip-Free Mechanism, Visual Trip Indicator |
The B curve indicates that the magnetic trip point is set between 3 and 5 times the rated current. This makes it ideal for resistive loads or applications where low levels of inrush current are expected, such as heaters, control circuits, or long wire runs.
The "-NA" designation indicates that the breaker is UL 489 listed for branch circuit protection in North America. This allows it to be used as a primary overcurrent device, unlike UL 1077 supplementary protectors.
Yes, Eaton FAZ-NA miniature circuit breakers are suitable for reverse feed applications, allowing power to be supplied from either the top or bottom terminals.
Yes, Eaton FAZ-NA breakers with a current rating of 20 amps or less are SWD rated, meaning they can be safely used on a regular basis to switch fluorescent lighting loads on and off.
Yes, the FAZ-NA series supports a variety of modular accessories that mount directly to the side of the breaker, including auxiliary switches, alarm contacts, and shunt trips.
Yes, it features a current limiting design that interrupts fault currents within one half cycle. This fast response reduces damaging let-through energy to protect downstream equipment and wiring.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.