Eaton / Cutler-HammerFAZ-D30/3-NA
Quantity
New
Quantity
Eaton / Cutler-HammerFAZ-D30/3-NA
Eaton / Cutler-HammerFAZ-C15/3-NA
Eaton / Cutler-HammerFAZ-D13/3-NA
Eaton / Cutler-HammerFAZ-D10/3-NA
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-D35/3-NA |
| Series | FAZ-NA |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | DIN Rail |
| Voltage | 240VAC, 96VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC, 10kA @ 96VDC |
| Frame Type | FAZ |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | DIN Rail Panels, Industrial Control Panels |
| Wire Gauge | 18-6 AWG |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | D |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Lockout Attachment, Busbar System |
|---|---|
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | ABS, CCC, CE, CSA, DNV, GL, IEC, Lloyd's, RoHS, UL, VDE |
| Temp Rating | -40C to 75C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Trip-Free Mechanism, Visual Trip Indicator |
The D-curve provides a magnetic trip point of 10 to 20 times the rated current. This makes it ideal for highly inductive loads with high inrush currents, such as motors, transformers, and power supplies.
Yes, the FAZ-NA series is UL 489 listed for branch circuit protection. It can be used in place of UL 1077 supplementary protectors, but UL 1077 devices cannot be used to replace UL 489 breakers.
Yes, this breaker supports reverse feeding. Power can be supplied to either the line or load terminals without affecting the performance or protection capabilities of the device.
Yes, it includes a trip-free mechanism. The breaker will safely interrupt a fault even if the handle is physically held or locked in the ON position.
As a current-limiting device, it interrupts fault currents within one-half cycle. This rapid response significantly reduces peak let-through current and energy, minimizing potential damage to the circuit.
Yes, the front of the breaker features a color-coded indicator. It displays red when the contacts are closed (ON) and green when the contacts are open (OFF) for immediate visual verification.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.