Eaton / Cutler-HammerFAZ-D10/3-NA
Quantity
New
Quantity
Eaton / Cutler-HammerFAZ-D10/3-NA
Eaton / Cutler-HammerFAZ-D13/3-NA
Eaton / Cutler-HammerFAZ-C15/3-NA
Eaton / Cutler-HammerFAZ-D30/3-NA
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-D6/3-NA |
| Series | FAZ-NA |
| Amperage | 6A |
| Poles | 3 |
| Mounting Style | DIN Rail |
| Voltage | 480Y/277VAC, 96VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 480Y/277VAC, 10kA @ 96VDC |
| Frame Type | FAZ |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | DIN Rail Systems, Industrial Control Panels |
| Wire Gauge | 18-6 AWG |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | D |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Lockout Attachment, Busbar System |
|---|---|
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489, RoHS |
| Approval | ABS, CCC, CE, CSA, DNV, HACR, IEC, Lloyd's, RoHS, SWD, UL, VDE |
| Temp Rating | -25C to 75C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Common Trip, Trip-Free Mechanism, Visual Trip Indicator, RoHS Compliant |
This breaker features a D-curve trip characteristic, making it ideal for applications with high inrush currents. Common uses include motor control circuits, transformers, and power supplies.
The D-curve magnetic trip point operates at 10 to 20 times the rated current. This high threshold prevents nuisance tripping in highly inductive applications.
It is designed for quick installation on standard 35mm DIN rail systems.
Yes, this model serves as a direct replacement for the legacy Eaton WMZT3D06 circuit breaker.
Yes, it is a UL 489 listed miniature circuit breaker, meaning it is fully rated for feeder and branch circuit protection. It can also be used in applications where UL 1077 supplementary protectors are permitted.
Yes, the FAZ-NA series utilizes a current limiting design that interrupts fault currents within one half cycle. This reduces the peak let-through energy that can damage downstream circuit components.
Yes, power to this circuit breaker can be fed from either the line side or the load side.
Yes, it features a trip-free design. The breaker will trip under fault conditions even if the operating handle is physically held in the ON position.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.