Eaton / Cutler-Hammer HFD2225 Molded Case Circuit Breaker

  • 225A
  • 2 Pole
  • Bolt-On
Eaton / Cutler-Hammer HFD2225
Molded Case Circuit Breaker
Brand Eaton / Cutler-Hammer
SKU HFD2225
Select Item Condition
Earn 1624 SuperPoints
  • 225A
  • 2 Pole
  • Bolt-On

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Eaton / Cutler-Hammer HFD2225 - 225A 2 Pole Molded Case Circuit Breaker

Eaton / Cutler-Hammer HFD2225 - 225A 2 Pole Molded Case Circuit Breaker

New

$1,624.00 In Stock

Quantity

Similar Items

Description

Designed for heavy-duty commercial use, the Eaton HFD2225 is a 225A thermal-magnetic MCCB in the Series C F-Frame lineup. Equipped with load-side lugs, it is engineered for bolt-on installation in Eaton panelboards and switchboards. It replaces legacy systems and is succeeded by the PDG22M0225TFFL. With an interrupting rating of 65kAIC at 480VAC, it safely clears severe faults. The breaker is UL 489 listed, HACR rated, and supports reverse feeding.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Part Number HFD2225
Series HFD
Amperage 225A
Poles 2
Mounting Style Bolt-On
Voltage 240VAC, 480VAC, 600VAC, 250VDC
Phase 1
AIC Rating 100kA @ 240VAC, 65kA @ 480VAC, 25kA @ 600VAC, 22kA @ 250VDC
Fit and installation
Frame Type FD
Terminal Type Lugs
For Use With Eaton Series C Panelboards, Switchboards, Motor Control Centers
Wire Gauge 4 AWG - 4/0 AWG (Cu/Al)
Max Wire 4/0 AWG
Min Wire 4 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Handle Lock
Accessories Load Side Lugs (Included)
Standards CSA C22.2 No. 5, HACR Rated, IEC 60947-2, NEMA AB-1, UL 489
Approval CSA, UL
Temp Rating 40C
Construction Features HACR Rated, High Interrupting Capacity, Reverse Feed, Non-Interchangeable Trip

Product FAQs

8 answers
Can the Eaton HFD2225 replace an older Cutler-Hammer or Westinghouse HFD2225?

Yes. Eaton acquired the Westinghouse distribution equipment division and continued manufacturing the Series C line under the Cutler-Hammer and Eaton brands. An Eaton HFD2225 is physically and electrically interchangeable with older Cutler-Hammer and Westinghouse breakers sharing the same catalog number.

What is the difference between the Eaton FD2225 and the HFD2225?

Both are 225-amp, 2-pole Series C F-frame circuit breakers with identical physical dimensions. The difference is their interrupting capacity. The standard FD2225 is rated for 35 kAIC at 480VAC, while the HFD2225 is a high-interrupting breaker rated for 65 kAIC at 480VAC.

What is the recommended tightening torque for the standard lugs on the HFD2225?

The standard TA225FD1 aluminum lugs on this breaker require a tightening torque of 120 lb-in (13.6 N.m) for the wire binding screws. Always use a calibrated torque wrench to prevent terminal overheating or nuisance tripping.

Is the HFD2225 circuit breaker suitable for reverse feed applications?

Yes. Eaton Series C thermal magnetic F-frame circuit breakers do not have line and load restrictions, making them suitable for reverse feed wiring in control panels and switchboards.

What types of enclosures and equipment are compatible with the HFD2225?

This F-frame breaker is designed for use in Eaton Series C panelboards, switchboards, motor control centers, and individual industrial enclosures that accept bolt-on F-frame breakers.

Can the HFD2225 be used in DC voltage systems?

Yes, this thermal magnetic breaker is rated for up to 250VDC with a maximum interrupting capacity of 22 kAIC. Electronic trip F-frame breakers do not carry this DC rating, making the thermal magnetic HFD2225 the correct choice for these applications.

Does the HFD2225 require a specific wire material?

The standard TA225FD1 lugs installed on this breaker are dual-rated for both copper (Cu) and aluminum (Al) conductors ranging from 4 AWG to 4/0 AWG. When using aluminum wire, applying a suitable joint compound is recommended to prevent oxidation.

What does the "LI" trip function mean on the HFD2225?

The "LI" designation indicates that the thermal magnetic trip unit provides Long-Time (L) protection for overloads and Instantaneous (I) protection for short circuits. Both the thermal and magnetic trip points are fixed on this specific model and cannot be adjusted in the field.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.

Reviews

5.0
Rated 5.0 out of 5 stars
Based on 21 reviews
Rating
Ratings
21 reviews
  • CH
    carl h.
    Verified Buyer
    Reviewing
    Eaton / Cutler-Hammer HFD3200 - 200A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    8/20/26
    Breaker

    Breaker shipped out and we received it super quick.

  • DL
    Deanna L.
    Verified Buyer
    Reviewing
    Eaton / Cutler-Hammer HFD3150 - 150A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    8/19/26
    Eaton / Cutler-Hammer HFD3150 - 150A 3 Pole Molded Case Circuit Breaker

    We needed more breakers ASAP and once again, Michael David came thru like he always does. We are a 24/7/ emergency electrical restoration companyso most of our orders are always needed in a rush and SuperBreakers is always my go to!.

  • RF
    Ron F.
    Verified Buyer
    Reviewing
    Eaton / Cutler-Hammer HFD3045 - 45A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    4/9/26
    HFD3045

    Perfect breaker & great price/delivery. It's very easy to schedule around SB as their projected delivery times are accurate.

  • CP
    Christopher P.
    Verified Buyer
    Reviewing
    Eaton / Cutler-Hammer HFD3020L - 20A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    2/13/26
    Fast and Cost effective

    Superbreakers Is always my first palce to look for harder to source breakers for a good price, and fast turnaround.

  • DS
    David S. B. D.
    Verified Buyer
    Reviewing
    Eaton / Cutler-Hammer HFD3060 - 60A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    2/6/26
    Breaker

    Great response time and product